WhatsApp

Article

The power-plant water play: push cooling towers to higher cycles, and feed them reclaimed effluent

beta-pramesti-asiaindustry-power-generation-combinedprocess-ccgt

The power-plant water play: push cooling towers to higher cycles, and feed them reclaimed effluent

Utilities and vendors have data on this. Run cooling towers at the highest safe cycles of concentration and switch makeup to [treated municipal wastewater](https://beta.co.id/en/blog/power-plants-slash-freshwater-use-by-driving-cooling-towers-to-higher-cycles-and-tapping-city-sewage). Water use can fall by 20–40% or more. Sometimes the payback is a few months.

Industry: Power_Generation_(Combined_Cycle_Gas_Turbine_ | Process: _CCGT)

Cooling towers are among the biggest water users on site. Commercial towers can use up to 35% of a facility's water. Industrial towers can use up to 95% (www.prochemtech.com). Therefore combined-cycle gas turbine (CCGT) operators watch two levers closely. The first is to run the system at higher cycles of concentration (COC, the ratio of dissolved solids in recirculating water to those in makeup) without scaling. The second is to replace potable makeup with other sources such as treated municipal wastewater.

Both can be measured. Raising cycles from 2 to 6 can cut makeup water by about 40%. It can also cut blowdown (the discharge needed to control solids) by roughly 80% (setpointsystems.com). EPA data show the same trend. Increasing cycles from 3 to 6 can reduce cooling‑tower water use by around 20% (nepis.epa.gov).

A 1,000‑ton tower shows the point. At COC ≈ 2.2 it needed ~17.8×10^6 gallons/year of makeup. At COC ≈ 10 the makeup fell to ~10.8×10^6 gallons/year, about 40% less (www.prochemtech.com).

High‑cycle operation and treatment program

Higher cycles concentrate scale-forming species such as calcium, magnesium, silica, and phosphate. Therefore prevention is the constraint, not desire. Removing hardness by softening allowed one facility to run safely at 10× concentration. It reduced annual water use by ~7.0×10^6 gallons and saved about $78.8k per year (www.prochemtech.com). A 1,000-gpm softener (~$26k CAPEX) paid back in roughly four months (www.prochemtech.com).

In practice, many untreated towers run at only 4–6× COC. Pushing past that usually needs a chemical program (polyphosphates, antiscalants, pH control) and sometimes softening (nepis.epa.gov). Plants build these programs around scale inhibitors and automated chemical feed using a dosing pump, tied to conductivity-based blowdown control (nepis.epa.gov).

Where hardness is the main problem, cation softening is proven to allow very high COC without scale (www.prochemtech.com). Towers that use softened makeup at 10× COC have reported corrosion below 0.5 mil/yr (mil/yr = thousandths of an inch per year, a corrosion rate) (www.prochemtech.com). Corrosion control usually goes together with corrosion inhibitors to protect the metallurgy at higher cycles.

The risk profile changes with source water. Reclaimed water usually carries more phosphate. This phosphate can precipitate calcium phosphate if there are no special inhibitors or pretreatment (www.powermag.com, www.watertechonline.com).

Blowdown recovery membrane systems

Higher cycles are not the only way to save water. Recovering blowdown raises the limit. One pilot reverse osmosis (RO, a pressure-driven membrane process that removes dissolved salts) recovered 96% of cooling tower blowdown water (www.watertechonline.com). A recent demonstration unit (48 m^3/day) reached the same 96% recovery. Conventional RO is limited to about 55–60% recovery. The unit got past this limit by adding a precipitation step after the RO. Such systems need a lot of capital. However, they can cut net usage and fees a lot where water and discharge limits are tight (www.watertechonline.com). Plants that look at this route usually want modular membrane systems that fit the existing utilities and footprint.

Reclaimed water as makeup supply

As freshwater supplies tighten, power plants increasingly turn to treated municipal wastewater (“reclaimed water”) for cooling. This shift is now common in the U.S., especially in arid regions, as global water stress meets the sector’s large demand (www.powermag.com). In drought‑prone areas, nearly all new plants and many retrofits use reclaimed makeup (www.powermag.com).

Tampa Electric’s Polk Station (combined‑cycle gas) built a 15‑mile pipeline to deliver up to 5 MGD (million gallons per day) of treated municipal effluent. This replaced about 3 MGD of groundwater formerly used for cooling (www.powermag.com, www.powermag.com). Under a 30‑year deal the city supplies this water free for 20 years. Southwest Florida agencies contributed about $47.5 million of the $120 million project cost, recognizing the environmental benefit. This reduces bay nutrient loads by roughly half of Tampa Bay’s five‑year target (www.powermag.com, www.powermag.com).

Reclaimed water has a different chemistry from freshwater. It usually carries more ammonia, organics and especially phosphate. The phosphate can cause calcium phosphate scale if it is not controlled (www.powermag.com). Some supplies need more treatment before they can safely replace municipal makeup. This can be extra chemistry, or units such as lime softeners or RO. With the right treatment and monitoring, they can supply cooling towers indefinitely. A U.S. chemical plant showed this. It ran stably on reclaimed effluent with extra polymer chemistry (www.powermag.com). Programs usually add oxidant and biological control with targeted biocides to manage organics.

In Indonesia and similar markets, reuse is still new. One Indonesian food plant recycled its internal wastewater. It added ultrafiltration (UF, a membrane pretreatment that removes fine suspended solids) before RO to make makeup water. This cut fresh PDAM/well use by about 5.46 m^3/day, roughly 5–15% of its original tower demand (jurnal.polinema.ac.id). Plants that use this approach usually pair ultrafiltration with brackish-water RO to meet tower‑makeup specs.

In Bali, a resort’s wastewater treatment plant recharges gardens with 3,200 m^3/day reclaimed water, priced at around Rp 6,812/m^3 (~$0.46/m^3) (www.mdpi.com). Surveys of reuse potential there suggest reclaimed water could meet additional cooling and landscaping demands (www.mdpi.com and www.mdpi.com). However, regulations lag. There are currently no national guidelines for industrial water reuse in Indonesia (www.mdpi.com).

Cost–benefit and payback windows

For higher COC via treatment upgrades, the extra costs are usually small compared with the savings. In the Phoenix case above, a softener of about $26k (plus about $12k for installation) gave more than $78k per year in savings (www.prochemtech.com). That is a payback of about four months. The shift came from lower water purchases ($200k → $121k) and lower sewer costs (www.prochemtech.com, www.prochemtech.com). Even without softening, better chemical control helps. If we compare hard‑water COC = 2 with softened COC = 10, the net annual cost dropped from about $246k to $168k (www.prochemtech.com, www.prochemtech.com). Chemical supply for high‑cycle operation usually comes under a cooling‑tower chemical program.

Reclaimed water projects can need heavy upfront investment. However, they deliver benefits that last. The Polk recycled-water project cost about $120 million (15-mile pipeline plus purification). About $47.5 million of that was subsidized (www.powermag.com). In return, the plant gained a secure 5 MGD supply and avoided groundwater pumping. The region also got a major cut in nutrient discharge that met bay cleanup targets (www.powermag.com). The nominal cost per volume is high, about $24/1000 gallons built. However, government grants and the avoided external costs changed the balance.

On‑site reuse needs much less capital. A small RO/UF skid might cost under $100k, and it pays for itself over years through saved water and sewer charges. In Bali, reclaimed water sells for about $0.46/m^3 (www.mdpi.com), against potable at roughly 0.2–0.4. Programs are usually rounded out with consumables and parts, supported by water‑treatment ancillaries.

To find the net benefit, weigh the extra chemical, equipment and power cost against the water and sewer savings and the compliance costs. In regions short of water, water usually costs several dollars. Every cubic meter saved, for example $0.5/m^3 at PDAM rates, directly cuts operating expense. Pollution or discharge fees also fall. For large projects (pipeline, RO plants), detailed economic studies compare the avoided purchase and permit costs plus environmental credits against the capital. Polk's project secured about 1.83×10^9 gallons/year (5 MGD) of freshwater supply. On a baseline calculation, that supply would have cost ~$X million per year if sourced conventionally. The SWFWMD subsidy recognised its long-term basin benefits (www.powermag.com). Even for smaller plants, simple payback is usually under a few years. The softening case above had under a 0.5-year ROI (www.prochemtech.com).

Savings potential and control limits

Maximizing COC to the highest point short of scaling can slash makeup needs by tens of percent. EPA and case‑study data point to 20–40% lower usage (nepis.epa.gov, setpointsystems.com). Combining high‑cycle operation with blowdown recovery and reclaimed‑water makeup multiplies savings, provided programs manage scale, fouling, and corrosion with the right chemistry and monitoring.

Notes and sources

This article draws on industry studies and case reports. These include cooling-water treatment analyses (www.prochemtech.com, www.prochemtech.com), DOE/EPA guides (nepis.epa.gov), power-industry journals (www.powermag.com, www.powermag.com), and technical papers on reuse and cooling-mode performance (www.watertechonline.com, www.mdpi.com). All numerical figures and outcomes above come from these sources (setpointsystems.com, www.prochemtech.com, www.powermag.com, jurnal.polinema.ac.id, www.mdpi.com).