Skip to content
English

Betaqua Reverse Osmosis

PT Beta Pramaesti Asia


Seawater Reverse Osmosis

SW 4-3E to SW 4-12E
0.2 m3/hour to 6 m3/hour (per unit)

SW 4-3E to SW 4-12E

SW 4-3E to SW 4-12E Capacity: 0.2 m3/hour to 6 m3/hour (per unit)

Model Membrane Qty Permeate Flowrate Feed Flowrate Flowrate Conc. Pipe Size Feed Pipe Size Permeate Pipe Size Conc. Frame Size L (mm) Frame Size L (mm) Frame Size W (mm) Frame Size H (mm) Frame Size H' (mm) Power (KW)
SW4-3 3 0.38 1.31 0.93 1 1 1 904 1275 830 1882 830 3
SW4-4 4 0.5 1.47 0.97 1 1 1 904 1275 830 1882 830 3
SW4-5 5 0.6 1.56 0.96 1 1 1 1112 1275 830 1882 830 3
SW4-6 6 0.75 1.87 1.12 1 1 1 1112 1275 830 1882 830 5.5
SW4-8 8 1 2.5 1.5 1 1 1 1320 1275 830 1882 830 7.5
SW4-12 12 1.5 3.75 2.25 1 1 1 1736 1275 830 1882 830 15

 

Standard Features:

  • Multi-Stage Pump
  • 5 micron cartridge filter
  • AW PVC for low pressure piping
  • Stainless steel high pressure piping/hose
  • Automatic inlet valve
  • Automatic flush valve
  • Mini PLC controller with display status
  • Chemical dosing system: Anti-scalant
  • PE Pre-filtration Cartridge Housing
  • Cleaning-in-place (CIP) system mounted to frame

Configuration:

  • Single Pass
  • Double Pass

Operating Parameters:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Application:

  • Boiler water heating
  • Drinking water
  • Pretreatment polishing (such as EDI/Mixed Bed)
  • Industrial applications where low dissolved solids solutions are required
  • Textile
  • Steel mills
  • Pharmaceutical
  • Residential
  • Water recycling

Instrumentation:

  • Pre Cartridge Filtration, Post Cartridge Filtration, membrane inlet and outlet, and Concentrate Pressure gauge.
  • Conductivity / TDS product
  • Low Pressure alarm
  • High Pressure Alarms
  • Flow Indicator (Rotameter): Product and Concentrate
  • Autoflush valve: Diaphragm valve
  • Automatic feed valve: Diaphragm valve

Materials of Construction:

  • Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 304 Sch 20

SW 4-3E to SW 4-12ESW 4-3E to SW 4-12E

Optional Features (Quoted Separately):

  • Stainless Steel Frame
  • Stainless steel piping for permeate and concentrate
  • Remote monitoring system with built-in web-based modem
  • 4-20mA output or other communication for external monitoring
  • Additional chemical dosing system
  • ORP monitoring system
  • Butterfly valve system

Seawater Reverse Osmosis

SW 8-4E hingga SW 8-160E

SW 8-4E to SW 8-160E Capacity: 1 m3/h to 100 m3/h (per unit)

Standard Features:

  • High pressure SWRO Multi Stage Pump
  • 5 micron cartridge filter
  • AW PVC for low pressure piping
  • Stainless steel High pressure piping
  • Automatic valve
  • Automatic flush valve
  • Mini PLC controller with status display
  • Chemical dosing system: Anti-scalant
  • Cleaning-in-place (CIP) system

Specifications:

Model

Membrane Qty

Permeate Flowrate

Feed Flowrate

Flowrate Conc.

Pipe Size Feed

Pipe Size Permeate

Pipe Size Conc.

Frame Size

L (mm)

W(mm)

H (mm)

Power (KW)

BW 8-8 E

8

5

7.1

2.1

1.5

1.5

1

4-2

5350

1520

1250

7.5

BW 8-12 E

12

10

14.3

4.3

2

1.5

1.5

4-3

5350

1520

1650

11

BW 8-20 E

20

15

21.4

6.4

2.5

2.5

1.5

4-5

5350

1520

2200

15

BW 8-25 E

25

20

28.6

8.6

2.5

2.5

1.5

5-5

6350

1520

2200

18.5

BW 8-30 E

30

25

35.7

10.7

3

2.5

1.5

5-42

6350

1870

2200

22

BW 8-35 E

35

30

42.9

12.9

3

2.5

1.5

5-43

6350

1870

1850

30

BW 8-40 E

40

35

50

15

4

3

2

5-54

6350

1870

2200

37

BW 8-45 E

45

40

57.1

17.1

4

3

2

5-54

6350

1870

2200

45

BW 8-50 E

50

45

64.3

19.3

4

3

2.5

5-55

6350

1870

2200

55

BW 8-55 E

55

50

71.4

21.4

4

3

2.5

6-55

7350

1870

2200

55

BW 8-60 E

60

55

78.6

23.6

4

3

2.5

6-55

7350

1870

2200

65

BW 8-66 E

66

60

85.7

25.7

4

3

2.5

6-66

7350

1870

2200

75

BW 8-72 E

72

65

92.9

27.9

5

3

2.5

6-66

7350

1870

2200

75

BW 8-78 E

78

70

100

30

5

3

2.5

6-553

7350

2220

2200

75

BW 8-84 E

84

75

107.1

32.1

6

3

3

6-554

7350

2220

2200

90

BW 8-90 E

90

80

114.3

34.3

6

3

3

6-554

7350

2220

2550

90

BW 8-96 E

96

85

121.4

36.4

6

3

3

6-555

7350

2220

2550

90

BW 8-102 E

102

95

135.7

40.7

6

3

3

6-665

7350

2220

2550

90

BW 8-108 E

108

100

142.9

42.9

6

3

3

6-666

7350

2220

2550

110

Operation Parameters:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Applications:

  • Boiler water heater
  • Fresh water systems
  • Industrial water treatment
  • Power plants
  • Steel mills
  • Pharmaceutical
  • Housing
  • Seawater treatment

Configuration:

  • Single Pass
  • Double Pass

Instrumentation:

  • Pre Cartridge Filtration, Post Cartridge Filtration, membrane inlet and outlet, and Concentrate Pressure gauge.
  • Conductivity / TDS product
  • Low Pressure alarm
  • High Pressure Alarms
  • Flow Indicator (Rotameter): Product and Concentrate
  • Autoflush valve: Diaphragm valve / Ball valve

SW 8-4E hingga SW 8-160E

Materials of Construction:

  • Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 316 Sch 40

Brackish Water Reverse Osmosis

BW 4-1E to BW 4-24E Capacity: 0.2 m3/h to 6 m3/h (per unit)

SW 8-4E hingga SW 8-160E

Standard Features:

  • Multi Stage Pump
  • 5 micron cartridge filter
  • Stainless steel high pressure piping
  • Automatic flush valve
  • CIP (Clean-in-Place) system
  • Mini PLC controller with status display
  • Anti-scalant dosing system
  • PE cartridge housing for pre-filtration

Here is the text of the table in the figure:

Model

Membrane Qty

Permeate Flowrate

Feed Flowrate

Flowrate Conc.

Pipe Size Feed

Pipe Size Permeate

Pipe Size Conc.

Frame Size

L (mm)

L' (mm)

W(mm)

H (mm)

H' (mm)

Power (KW)

BW 4-1 E

1

0,175

1,2

1,025

0,5

0,5

0,5

1

1000

1250

600

1780

1100

1

BW 4-2 E

2

0,36

1,4

1,04

0,5

0,5

0,5

1

1000

1250

600

1780

1100

1,1

BW 4-3 E

3

0,55

1,6

1,05

1

0,5

0,5

1

1000

1250

600

1780

1100

1,3

BW 4-4 E

4

0,72

1,7

0,98

1

0,5

0,5

1

1000

1250

600

1780

1100

1,3

BW 4-6 E

6

1,1

2

0,9

1

0,5

0,5

1

1000

1250

600

1780

1100

1,6

BW 4-8 E

8

1,45

2,4

0,95

1

0,75

0,5

1 / (3-4)

1000

1250

600

1780

1100

2

BW 4-9 E

9

1,6

3,2

1,6

1

0,75

0,5

1 / (3-3)

1000

1250

600

1780

1100

2,5

BW 4-12 E

12

2,2

4,1

1,9

1

0,75

0,75

3-4

1000

1250

600

1780

1100

3,2

BW 4-15 E

15

2,75

5

2,25

1,5

1

1

3-32

4000

1250

1000

1550

1100

4,75

BW 4-18 E

18

3,25

6,6

2,75

1

1

1

3-33

4000

1250

1000

1550

1100

5,5

BW 4-21 E

21

3,8

6,6

2,8

1,5

1

1

3-43

4000

1250

1000

1550

1100

5,5

BW 4-24 E

24

4,35

8,1

3,75

1,5

1

1

3-44

4000

1250

1000

1550

1100

6,5

That is the text of the table in the figure.

Operation Parameter:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Applications:

  • Boiler water heating
  • Drinking water
  • Industrial water treatment
  • Textile mills
  • Pharmaceutical
  • Housing
  • Repeat water treatment

Configuration:

  • Single Pass
  • Double Pass

Instrumentation:

  • Pre-cartridge filtration, post cartridge filtration, membrane inlet and outlet and concentrate pressure gauge.
  • Conductivity / TDS product
  • Low pressure alarms
  • High pressure alarms
  • Flow indicator (rotameter): product and concentrate
  • Autoflush valve: diaphragm valve
  • Automatic feed valve: diaphragm valve

SW 8-4E hingga SW 8-160ESW 8-4E hingga SW 8-160E

Materials of Construction:

  • Membrane Housing: FRP (Fibber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 304 Sch 20

Optional Features (Quoted Separately):

  • Stainless steel frame
  • Remote monitoring system
  • Additional chemical dosing system
  • ORP monitoring system
  • Butterfly valve system

Brackish Water Reverse Osmosis

BW 8-8E to BW 8-108E Capacity: 5 m3/h to 100 m3/h (per unit)

membrane ro

Standard Features:

  • Multi-stage pump
  • 5 micron cartridge filter
  • Stainless steel for high pressure piping
  • Automatic flush valve
  • CIP system
  • Mini PLC controller with status display
  • Anti-scalant dosing system
  • Cleaning-in-place (CIP) system

Model

Membrane Qty

Permeate Flowrate

Feed Flowrate

Flowrate Conc.

Pipe Size Feed

Pipe Size Permeate

Pipe Size Conc.

Frame Size

L (mm)

W(mm)

H (mm)

Power (KW)

BW 8-8 E

8

5

7,1

2,1

1,5

1,5

1

4-2

5350

1520

1250

7,5

BW 8-12 E

12

10

14,3

4,3

2

1,5

1,5

4-3

5350

1520

1650

11

BW 8-20 E

20

15

21,4

6,4

2,5

2,5

1,5

4-5

5350

1520

2200

15

BW 8-25 E

25

20

28,6

8,6

2,5

2,5

1,5

5-5

6350

1520

2200

18,5

BW 8-30 E

30

25

35,7

10,7

3

2,5

1,5

5-42

6350

1870

2200

22

BW 8-35 E

35

30

42,9

12,9

3

2,5

1,5

5-43

6350

1870

1850

30

BW 8-40 E

40

35

50

15

4

3

2

5-54

6350

1870

2200

37

BW 8-45 E

45

40

57,1

17,1

4

3

2

5-54

6350

1870

2200

45

BW 8-50 E

50

45

64,3

19,3

4

3

2,5

5-55

6350

1870

2200

55

BW 8-55 E

55

50

71,4

21,4

4

3

2,5

6-55

7350

1870

2200

55

BW 8-60 E

60

55

78,6

23,6

4

3

2,5

6-55

7350

1870

2200

65

BW 8-66 E

66

60

85,7

25,7

4

3

2,5

6-66

7350

1870

2200

75

BW 8-72 E

72

65

92,9

27,9

5

3

2,5

6-66

7350

1870

2200

75

BW 8-78 E

78

70

100

30

5

3

2,5

6-553

7350

2220

2200

75

BW 8-84 E

84

75

107,1

32,1

6

3

3

6-554

7350

2220

2200

90

BW 8-90 E

90

80

114,3

34,3

6

3

3

6-554

7350

2220

2550

90

BW 8-96 E

96

85

121,4

36,4

6

3

3

6-555

7350

2220

2550

90

BW 8-102 E

102

95

135,7

40,7

6

3

3

6-665

7350

2220

2550

90

BW 8-108 E

108

100

142,9

42,9

6

3

3

6-666

7350

2220

2550

110

That is the text of the table in the image.

Operation Parameters:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Configuration:

  • Single Pass
  • Double Pass

Materials of Construction:

  • Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 304 Sch 20

configuration membraneperspective view application

Application:

  • Boiler water heating
  • Fresh water treatment
  • Textile mills
  • Pharmaceutical industry
  • Industrial water treatment
  • Power plant

Learn more

Contact us to learn more about our Betaqua Reverse Osmosis and other info about our products and services.