Betaqua Reverse Osmosis
PT. Beta Pramaesti Asia
Seawater Reverse Osmosis
SW 4-3E to SW 4-12E
0.2 m3/hour to 6 m3/hour (per unit)
SW 4-3E hingga SW 4-12E Kapasitas: 0,2 m3/jam hingga 6 m3/jam (per unit)
Model | Membrane Qty | Flowrate Permeate | Flowrate Feed | Flowrate Conc. | Pipe Size Feed | Pipe Size Permeate | Pipe Size Conc. | Frame Size L (mm) | Frame Size L (mm) | Frame Size W (mm) | Frame Size H (mm) | Frame Size H' (mm) | Power (KW) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SW4-3 | 3 | 0.38 | 1.31 | 0.93 | 1 | 1 | 1 | 904 | 1275 | 830 | 1882 | 830 | 3 |
SW4-4 | 4 | 0.5 | 1.47 | 0.97 | 1 | 1 | 1 | 904 | 1275 | 830 | 1882 | 830 | 3 |
SW4-5 | 5 | 0.6 | 1.56 | 0.96 | 1 | 1 | 1 | 1112 | 1275 | 830 | 1882 | 830 | 3 |
SW4-6 | 6 | 0.75 | 1.87 | 1.12 | 1 | 1 | 1 | 1112 | 1275 | 830 | 1882 | 830 | 5.5 |
SW4-8 | 8 | 1 | 2.5 | 1.5 | 1 | 1 | 1 | 1320 | 1275 | 830 | 1882 | 830 | 7.5 |
SW4-12 | 12 | 1.5 | 3.75 | 2.25 | 1 | 1 | 1 | 1736 | 1275 | 830 | 1882 | 830 | 15 |
Fitur Standar:
- Pompa Multi Tahap
- Filter kartrid 5 mikron
- PVC AW untuk perpipaan tekanan rendah
- Pipa / selang tekanan tinggi baja tahan karat
- Katup masuk otomatis
- Katup flush otomatis
- Pengontrol PLC mini dengan status tampilan
- Sistem dosing kimia: Anti-scalant
- Housing Kartrid Pre-filtrasi PE
- Sistem pembersihan di tempat (CIP) dipasang ke rangka
Configuration:
- Single Pass
- Double Pas
Parameter Operasi:
- Pemulihan: 50-80%
- Suhu: 5-35 derajat C
- Tekanan masuk minimum: 2 bar
- Tingkat penolakan: 95-98%
Aplikasi:
- Pemanasan air ketel
- Air minum
- Pemolesan pretreatment (seperti EDI/Mixed Bed)
- Aplikasi industri yang memerlukan larutan padatan terlarut rendah
- Tekstil
- Pabrik baja
- Farmasi
- Perumahan
- Daur ulang air
Instrumentation:
- Pre Cartridge Filtration, Post Cartridge Filtration, membrane inlet and outlet, and Concentrate Pressure gauge
- Conductivity / TDS product
- Low Pressure alarm
- High Pressure Alarms
- Flow Indicator (Rotameter): Product and Concentrate
- Autoflush valve: Diaphragm valve
- Automatic feed valve: Diaphragm valve
Materials of Construction:
- Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
- Frame: Epoxy coated mild steel
- Permeate and Feed Piping: PVC AW
- High Pressure Piping: Stainless Steel 304 Sch 20
Fitur Opsional (Dikutip Secara Terpisah):
- Rangka Baja Tahan Karat
- Perpipaan baja tahan karat untuk permeat dan konsentrat
- Sistem pemantauan jarak jauh dengan modem bawaan berbasis web
- Output 4-20mA atau komunikasi lain untuk pemantauan eksternal
- Sistem dosing kimia tambahan
- Sistem pemantauan ORP
- Sistem katup kupu-kupu
Seawater Reverse Osmosis
SW 8-4E hingga SW 8-160E Kapasitas: 1 m3/jam hingga 100 m3/jam (per unit)
Fitur Standar:
- Pompa Multi Tahap SWRO bertekanan tinggi
- Filter kartrid 5 mikron
- PVC AW untuk perpipaan tekanan rendah
- Baja tahan karat Pipa bertekanan tinggi
- Katup otomatis
- Katup flush otomatis
- Pengontrol PLC Mini dengan status tampilan
- Sistem dosing kimia: Anti-scalant
- Sistem pembersihan di tempat (CIP)
Spesifikasi:
Model |
Membrane Qty |
Flowrate Permeate |
Flowrate Feed |
Flowrate Conc. |
Pipe Size Feed |
Pipe Size Permeate |
Pipe Size Conc. |
Frame Size |
L (mm) |
W (mm) |
H (mm) |
Power (KW) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
BW 8-8 E |
8 |
5 |
7.1 |
2.1 |
1.5 |
1.5 |
1 |
4-2 |
5350 |
1520 |
1250 |
7.5 |
BW 8-12 E |
12 |
10 |
14.3 |
4.3 |
2 |
1.5 |
1.5 |
4-3 |
5350 |
1520 |
1650 |
11 |
BW 8-20 E |
20 |
15 |
21.4 |
6.4 |
2.5 |
2.5 |
1.5 |
4-5 |
5350 |
1520 |
2200 |
15 |
BW 8-25 E |
25 |
20 |
28.6 |
8.6 |
2.5 |
2.5 |
1.5 |
5-5 |
6350 |
1520 |
2200 |
18.5 |
BW 8-30 E |
30 |
25 |
35.7 |
10.7 |
3 |
2.5 |
1.5 |
5-42 |
6350 |
1870 |
2200 |
22 |
BW 8-35 E |
35 |
30 |
42.9 |
12.9 |
3 |
2.5 |
1.5 |
5-43 |
6350 |
1870 |
1850 |
30 |
BW 8-40 E |
40 |
35 |
50 |
15 |
4 |
3 |
2 |
5-54 |
6350 |
1870 |
2200 |
37 |
BW 8-45 E |
45 |
40 |
57.1 |
17.1 |
4 |
3 |
2 |
5-54 |
6350 |
1870 |
2200 |
45 |
BW 8-50 E |
50 |
45 |
64.3 |
19.3 |
4 |
3 |
2.5 |
5-55 |
6350 |
1870 |
2200 |
55 |
BW 8-55 E |
55 |
50 |
71.4 |
21.4 |
4 |
3 |
2.5 |
6-55 |
7350 |
1870 |
2200 |
55 |
BW 8-60 E |
60 |
55 |
78.6 |
23.6 |
4 |
3 |
2.5 |
6-55 |
7350 |
1870 |
2200 |
65 |
BW 8-66 E |
66 |
60 |
85.7 |
25.7 |
4 |
3 |
2.5 |
6-66 |
7350 |
1870 |
2200 |
75 |
BW 8-72 E |
72 |
65 |
92.9 |
27.9 |
5 |
3 |
2.5 |
6-66 |
7350 |
1870 |
2200 |
75 |
BW 8-78 E |
78 |
70 |
100 |
30 |
5 |
3 |
2.5 |
6-553 |
7350 |
2220 |
2200 |
75 |
BW 8-84 E |
84 |
75 |
107.1 |
32.1 |
6 |
3 |
3 |
6-554 |
7350 |
2220 |
2200 |
90 |
BW 8-90 E |
90 |
80 |
114.3 |
34.3 |
6 |
3 |
3 |
6-554 |
7350 |
2220 |
2550 |
90 |
BW 8-96 E |
96 |
85 |
121.4 |
36.4 |
6 |
3 |
3 |
6-555 |
7350 |
2220 |
2550 |
90 |
BW 8-102 E |
102 |
95 |
135.7 |
40.7 |
6 |
3 |
3 |
6-665 |
7350 |
2220 |
2550 |
90 |
BW 8-108 E |
108 |
100 |
142.9 |
42.9 |
6 |
3 |
3 |
6-666 |
7350 |
2220 |
2550 |
110 |
Parameter Operasi:
- Pemulihan: 50-80%
- Suhu: 5-35 derajat C
- Tekanan masuk minimum: 2 bar
- Tingkat penolakan: 95-98%
Aplikasi:
- Pemanas air ketel
- Sistem air tawar
- Pengolahan air industri
- Pembangkit listrik
- Pabrik baja
- Farmasi
- Perumahan
- Pengolahan air laut
Configuration:
- Single Pass
- Double Pass
Instrumentation:
- Pre Cartridge Filtration, Post Cartridge Filtration, membrane inlet and outlet, and Concentrate Pressure gauge
- Conductivity / TDS product
- Low Pressure alarm
- High Pressure Alarms
- Flow Indicator (Rotameter): Product and Concentrate
- Autoflush valve: Diaphragm valve / Ball valve
Materials of Construction:
- Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
- Frame: Epoxy coated mild steel
- Permeate and Feed Piping: PVC AW
- High Pressure Piping: Stainless Steel 316 Sch 40
Brackish Water Reverse Osmosis
BW 4-1E hingga BW 4-24E Kapasitas: 0,2 m3/jam hingga 6 m3/jam (per unit)
Fitur Standar:
- Pompa Multi Tahap
- Filter kartrid 5 mikron
- Pipa tekanan tinggi baja tahan karat
- Katup flush otomatis
- Sistem CIP (Clean-in-Place)
- Pengontrol PLC mini dengan tampilan status
- Sistem dosing anti-scalant
- Housing kartrid PE untuk pre-filtrasi
Berikut adalah teks dari tabel pada gambar:
Model |
Membrane Qty |
Flowrate Permeate |
Flowrate Feed |
Flowrate Conc. |
Pipe Size Feed |
Pipe Size Permeate |
Pipe Size Conc. |
Frame Size |
L (mm) |
L' (mm) |
W (mm) |
H (mm) |
H' (mm) |
Power (KW) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BW 4-1 E |
1 |
0,175 |
1,2 |
1,025 |
0,5 |
0,5 |
0,5 |
1 |
1000 |
1250 |
600 |
1780 |
1100 |
1 |
BW 4-2 E |
2 |
0,36 |
1,4 |
1,04 |
0,5 |
0,5 |
0,5 |
1 |
1000 |
1250 |
600 |
1780 |
1100 |
1,1 |
BW 4-3 E |
3 |
0,55 |
1,6 |
1,05 |
1 |
0,5 |
0,5 |
1 |
1000 |
1250 |
600 |
1780 |
1100 |
1,3 |
BW 4-4 E |
4 |
0,72 |
1,7 |
0,98 |
1 |
0,5 |
0,5 |
1 |
1000 |
1250 |
600 |
1780 |
1100 |
1,3 |
BW 4-6 E |
6 |
1,1 |
2 |
0,9 |
1 |
0,5 |
0,5 |
1 |
1000 |
1250 |
600 |
1780 |
1100 |
1,6 |
BW 4-8 E |
8 |
1,45 |
2,4 |
0,95 |
1 |
0,75 |
0,5 |
1 / (3-4) |
1000 |
1250 |
600 |
1780 |
1100 |
2 |
BW 4-9 E |
9 |
1,6 |
3,2 |
1,6 |
1 |
0,75 |
0,5 |
1 / (3-3) |
1000 |
1250 |
600 |
1780 |
1100 |
2,5 |
BW 4-12 E |
12 |
2,2 |
4,1 |
1,9 |
1 |
0,75 |
0,75 |
3-4 |
1000 |
1250 |
600 |
1780 |
1100 |
3,2 |
BW 4-15 E |
15 |
2,75 |
5 |
2,25 |
1,5 |
1 |
1 |
3-32 |
4000 |
1250 |
1000 |
1550 |
1100 |
4,75 |
BW 4-18 E |
18 |
3,25 |
6,6 |
2,75 |
1 |
1 |
1 |
3-33 |
4000 |
1250 |
1000 |
1550 |
1100 |
5,5 |
BW 4-21 E |
21 |
3,8 |
6,6 |
2,8 |
1,5 |
1 |
1 |
3-43 |
4000 |
1250 |
1000 |
1550 |
1100 |
5,5 |
BW 4-24 E |
24 |
4,35 |
8,1 |
3,75 |
1,5 |
1 |
1 |
3-44 |
4000 |
1250 |
1000 |
1550 |
1100 |
6,5 |
Itu adalah teks dari tabel pada gambar.
Parameter Operasi:
- Pemulihan: 50-80%
- Suhu: 5-35 derajat C
- Tekanan masuk minimum: 2 bar
- Tingkat penolakan: 95-98%
Aplikasi:
- Pemanasan air ketel
- Air minum
- Pengolahan air industri
- Pabrik tekstil
- Farmasi
- Perumahan
- Pengolahan air ulang
Configuration:
- Single Pass
- Double Pass
Instrumentation:
- Pre-cartridge filtration, post cartridge filtration, membrane inlet and outlet and concentrate pressure gauge
- Conductivity / TDS product
- Low pressure alarm
- High pressure alarms
- Flow indicator (rotameter): product and concentrate
- Autoflush valve: diaphragm valve
- Automatic feed valve: diaphragm valve
Materials of Construction:
- Membrane Housing: FRP (Fibber Reinforced Plastics) 300 Psi
- Frame: Epoxy coated mild steel
- Permeate and Feed Piping: PVC AW
- High Pressure Piping: Stainless Steel 304 Sch 20
Fitur Opsional (Dikutip Terpisah):
- Rangka baja tahan karat
- Sistem pemantauan jarak jauh
- Sistem dosing kimia tambahan
- Sistem pemantauan ORP
- Sistem katup kupu-kupu
Brackish Water Reverse Osmosis
BW 8-8E hingga BW 8-108E Kapasitas: 5 m3/jam hingga 100 m3/jam (per unit)
Fitur Standar:
- Pompa Multi Tahap
- Filter kartrid 5 mikron
- Baja tahan karat untuk perpipaan tekanan tinggi
- Katup flush otomatis
- Sistem CIP
- Pengontrol PLC mini dengan tampilan status
- Sistem dosing anti-scalant
- Sistem pembersihan di tempat (CIP)
Model |
Membrane Qty |
Flowrate Permeate |
Flowrate Feed |
Flowrate Conc. |
Pipe Size Feed |
Pipe Size Permeate |
Pipe Size Conc. |
Frame Size |
L (mm) |
W (mm) |
H (mm) |
Power (KW) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
BW 8-8 E |
8 |
5 |
7,1 |
2,1 |
1,5 |
1,5 |
1 |
4-2 |
5350 |
1520 |
1250 |
7,5 |
BW 8-12 E |
12 |
10 |
14,3 |
4,3 |
2 |
1,5 |
1,5 |
4-3 |
5350 |
1520 |
1650 |
11 |
BW 8-20 E |
20 |
15 |
21,4 |
6,4 |
2,5 |
2,5 |
1,5 |
4-5 |
5350 |
1520 |
2200 |
15 |
BW 8-25 E |
25 |
20 |
28,6 |
8,6 |
2,5 |
2,5 |
1,5 |
5-5 |
6350 |
1520 |
2200 |
18,5 |
BW 8-30 E |
30 |
25 |
35,7 |
10,7 |
3 |
2,5 |
1,5 |
5-42 |
6350 |
1870 |
2200 |
22 |
BW 8-35 E |
35 |
30 |
42,9 |
12,9 |
3 |
2,5 |
1,5 |
5-43 |
6350 |
1870 |
1850 |
30 |
BW 8-40 E |
40 |
35 |
50 |
15 |
4 |
3 |
2 |
5-54 |
6350 |
1870 |
2200 |
37 |
BW 8-45 E |
45 |
40 |
57,1 |
17,1 |
4 |
3 |
2 |
5-54 |
6350 |
1870 |
2200 |
45 |
BW 8-50 E |
50 |
45 |
64,3 |
19,3 |
4 |
3 |
2,5 |
5-55 |
6350 |
1870 |
2200 |
55 |
BW 8-55 E |
55 |
50 |
71,4 |
21,4 |
4 |
3 |
2,5 |
6-55 |
7350 |
1870 |
2200 |
55 |
BW 8-60 E |
60 |
55 |
78,6 |
23,6 |
4 |
3 |
2,5 |
6-55 |
7350 |
1870 |
2200 |
65 |
BW 8-66 E |
66 |
60 |
85,7 |
25,7 |
4 |
3 |
2,5 |
6-66 |
7350 |
1870 |
2200 |
75 |
BW 8-72 E |
72 |
65 |
92,9 |
27,9 |
5 |
3 |
2,5 |
6-66 |
7350 |
1870 |
2200 |
75 |
BW 8-78 E |
78 |
70 |
100 |
30 |
5 |
3 |
2,5 |
6-553 |
7350 |
2220 |
2200 |
75 |
BW 8-84 E |
84 |
75 |
107,1 |
32,1 |
6 |
3 |
3 |
6-554 |
7350 |
2220 |
2200 |
90 |
BW 8-90 E |
90 |
80 |
114,3 |
34,3 |
6 |
3 |
3 |
6-554 |
7350 |
2220 |
2550 |
90 |
BW 8-96 E |
96 |
85 |
121,4 |
36,4 |
6 |
3 |
3 |
6-555 |
7350 |
2220 |
2550 |
90 |
BW 8-102 E |
102 |
95 |
135,7 |
40,7 |
6 |
3 |
3 |
6-665 |
7350 |
2220 |
2550 |
90 |
BW 8-108 E |
108 |
100 |
142,9 |
42,9 |
6 |
3 |
3 |
6-666 |
7350 |
2220 |
2550 |
110 |
Itu adalah teks dari tabel pada gambar.
Parameter Operasi:
- Pemulihan: 50-80%
- Suhu: 5-35 derajat C
- Tekanan masuk minimum: 2 bar
- Tingkat penolakan: 95-98%
Configuration:
- Single Pass
- Double Pass
Materials of Construction:
- Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
- Frame: Epoxy coated mild steel
- Permeate and Feed Piping: PVC AW
- High Pressure Piping: Stainless Steel 304 Sch 20
Aplikasi:
- Pemanasan air ketel
- Pengolahan air tawar
- Pabrik tekstil
- Industri farmasi
- Pengolahan air industri
- Pembangkit listrik