WhatsApp

Article

Steel’s Oily Secret: DAF vs. Ultrafiltration in the Race to Clean Mill Water

beta-pramesti-asiaindustry-steel-manufacturingprocess-wastewater-treatment-oily

Steel’s Oily Secret: DAF vs. Ultrafiltration in the Race to Clean Mill Water

Steel mills produce fine oil emulsions that gravity cannot separate. Two common methods, dissolved-air flotation and ultrafiltration, are used to remove them. Both work better with special demulsifiers and flocculants.

Industry: Steel_Manufacturing | Process: Wastewater_Treatment_(Oily,_Metals,_Cyanide)

From rolling draft to quench baths, steel plants make wastewaters that carry lubricants and grease, mixed with emulsified oils. These droplets are finer than 20 µm and simple gravity separation does not remove them. Gravity separation fails on these fine emulsions. Therefore plants use physico-chemical flocculation/flotation or membranes (MDPI) (LinkedIn).

DAF (dissolved-air flotation) is one of the most installed units. It is a micro-bubble flotation process that lifts flocculated droplets into a scum layer. UF (ultrafiltration) is a pressure-driven membrane step. It has a typical membrane molecular weight cut-off (MWCO) of about 10–100 kDa. It sieves out droplets and suspended solids outright.

How they stack up matters for footprint, chemicals, and the oil-and-grease (O&G) numbers mills must hit. How chemistry tips the balance matters too.

Oily wastewater characteristics and limits

Steel mills' emulsified oils (<20 µm droplets) from rolling draft and quench baths need treatment beyond gravity (MDPI) (LinkedIn). Before the core treatment, mills usually use primary physical steps, screens and free-oil skimming. Equipment such as primary separation systems, an automatic screen, or targeted free-oil removal can set up downstream performance.

DAF performance with and without chemistry

DAF injects micro-bubbles. The bubbles attach to flocculated droplets and carry them to the surface. In practice, DAF alone usually removes only about 50–70% of emulsified oil. An Iraqi refinery study found 60% oil removal with no coagulant (ResearchGate).

The fix is chemistry. With 25–30 mg/L cationic polyacrylamide (PAM) in DAF, oil removal reached ~94% (from 50 ppm influent). With alum alone it was 89%. A blend of alum + PAM reached ~99% removal (ResearchGate). Typical DAF effluent after such treatment may still contain tens of mg/L of oil/grease. Pilot data report UF permeates <100 mg/L and TSS (total suspended solids) very low (ResearchGate).

DAF needs a sizeable footprint (large tanks) and continuous sludge (scum) removal. Energy costs are modest. However, chemical costs (coagulants) can be high (ResearchGate) (LinkedIn). Where appropriate, integrated units like a compact DAF system help concentrate scum efficiently for removal.

Ultrafiltration membranes under load

UF membranes are usually polymeric hollow‑fiber or flat‑sheet with ~10–100 kDa MWCO. They retain almost all oil droplets and suspended solids. Pilot and full‑scale trials at refineries and factories consistently show very high oil rejection. Ostlund et al. reported permeate O&G <100 mg/L under continuous operation (ResearchGate).

One study used two spiral UF modules (MWCO 2–35 kDa). The finer membrane removed about 90% COD (chemical oxygen demand) and about 99.7% hydrocarbon (HC). It ran at a permeate flux of about 20 L/m²·hr, 400 kPa and 35°C (ResearchGate). A larger refinery UF project found O&G rejections of about 97–98%. The effluent was usually below 50 mg/L oil/grease (ResearchGate) (ResearchGate).

UF permeate easily meets oil targets below 100 mg/L and needs a small footprint. Therefore it is usually chosen for "polishing" after primary treatment (MDPI). Plants usually specify skid systems such as ultrafiltration units with proven UF/RO membranes to fit tight spaces.

The tradeoffs are real. UF is sensitive to oil fouling. Pores clog and surfaces foul as oils adhere. Therefore it needs regular cleaning and chemical clean‑in‑place (LinkedIn) (ResearchGate). Pretreatment can reduce fouling partly, for example skimmers or DAF to remove free oil, and so can membrane surface modification (hydrophilic coatings). Despite the cleaning, UF runs at a low operating pressure of about 0.2 bar. Therefore it is energy‑efficient at about 0.1–0.2 kWh/m³ (MDPI). Plants usually pair cleaning programs with compatible agents, for example through dedicated membrane cleaners.

Head‑to‑head: efficiency, footprint, chemicals

Removal efficiency: DAF with optimized coagulant dosing can approach UF levels. It removes about 94–99% of oil when dosed with PAM and/or alum (ResearchGate). UF tests consistently show about 97–99% oil rejection (ResearchGate) (ResearchGate).

In absolute terms, UF permeate concentrations are usually <50 mg/L O&G (ResearchGate). DAF effluent usually needs further treatment to reach such levels. Footprint and cost: UF systems have a much smaller hydraulic footprint, though the capital cost per volume is higher. DAF units are bulky and need large sludge handling. Chemicals: DAF needs coagulant/flocculant feed to achieve high removal. UF needs none except periodic cleaning. However, UF needs upstream oil removal, usually by skimming/DAF or coalescers, to prevent severe fouling (LinkedIn). DAF needs larger volumes for treatment and more chemical use. However, DAF handles variable loads well (ResearchGate) (LinkedIn).

Demulsifiers and flocculants: breaking stability

Stable oil‑water emulsions must be broken (demulsified) and droplets aggregated (flocculated) before removal. Demulsifiers, usually oil‑soluble surfactants or polymers, penetrate and destabilize the surfactant film on droplets. They reduce interfacial tension and neutralize surface charge. Once demulsified, flocculants (usually cationic polyacrylamides or coagulants like Fe/Al salts) neutralize remaining charge and bridge droplets into flocs. This drives coalescence and flotation (MDPI).

Example: adding 100 mg/L of an oil‑soluble demulsifier cut the oil–water interfacial tension from ~4.43 to 1.33 mN/m. It also reduced the droplet zeta potential (a measure of droplet surface charge) by ~60%, from –67.1 to –30.6 mV. This greatly destabilizes the emulsion (MDPI) (MDPI). In practice, the compounds used include cationic organic polymers, for example high‑molecular‑weight polyacrylamides and poly(diallyldimethylammonium chloride). These are sometimes grafted onto magnetic particles or supports so they are easy to remove. Inorganics such as polyaluminum chloride (PAC) or ferric chloride are also used. For DAF specifically, adding just 25 ppm PAM raised oil removal to ~94% (ResearchGate).

New demulsifier‑based flocculants are pushing doses lower. A magnetic chitosan‑polymer composite (FS‑MC) at only 2–3 mg/L removed ~93–95% of emulsified oil. A polymer blend (2–4 mL/L) achieved ~95.8% oil removal from steel rolling wastewater (ResearchGate) (ResearchGate). These flocculants combine hydrophobic and cationic groups. Therefore they maximize bridging and charge neutralization.

In real systems, demulsification and flocculation upstream of DAF (or pretreatment to UF) bring the oil concentration down very low. Bench experiments report that oil "clarity" (TCOD or turbidity) drops by >90% after optimized demulsifier and flocculant dosing. The dosage is usually in the 1–100 mg/L range, depending on the oil load. Jar tests tailor the pick so the droplets grow big enough to float effectively (ResearchGate) (ResearchGate).

Accurate chemical feed with a dosing pump also matters. So does the right choice from demulsifiers, coagulants and flocculants. Together they keep the separation consistent.

What the studies say—one view

Modern reviews and studies confirm the main trends. UF membranes usually exceed 97% oil rejection (ResearchGate). DAF with coagulant sits near 95–99% (ResearchGate). Strong flocculants and demulsifiers can reach more than 90% removal at very low dose (ResearchGate) (MDPI). UF is compact. DAF needs larger volumes and more chemicals. However, DAF keeps working when the load changes (ResearchGate) (LinkedIn).

Study references

  • Albarazanje, M. G. et al. Study the Performance of Dissolved Air Flotation as Industrial Wastewater Treatment Method, Eng. Techn. J. 37‑C(3), 333–343 (2019) (ResearchGate).
  • Reed, B. et al. Oily Wastewater Treatment by Ultrafiltration: Pilot‑Scale Results and Full‑Scale Design, Pract. Period. Hazard. Toxic Radioact. Waste Mgmt. 2(3), 100–110 (1998) (ResearchGate) (ResearchGate).
  • Huang, B. et al. Demulsification–Flocculation Mechanism of Oil–Water Emulsion, Polymers 11(3), 395 (2019) (MDPI).
  • Chen, J. H. et al. Cov. Bonded Magnetic Flocculant for Emulsified Oil Removal, J. Hazard. Mater. 410, 124367 (2021) (ResearchGate).
  • Abuhasel, K. et al. Oily Wastewater Treatment: Conventional and Modern Methods, Water 13(7), 980 (2021) (Review article) (MDPI).