Inside the steel mill that cleans oil, metals, and cyanide — by design
Inside the steel mill that cleans oil, metals, and cyanide — by design
A centralized wastewater plant built for shock loads and strict discharge limits uses classic physics, targeted chemistry and hybrid biology to tame some of industry's toughest effluents.
A modern integrated steel mill uses about 28.6 m³ of process water per tonne of steel (www.mdpi.com). It sends back waste streams that vary a lot and carry many pollutants. A municipal plant cannot treat that water.
Coking and [blast‑furnace operations](https://beta.co.id/en/blog/inside-the-race-to-retune-the-blast-furnace-pci-natural-gas-and-ccs) load up organics (COD, BOD), ammonia, phenols, cyanide and oils far beyond typical municipal values. One coke‑oven wastewater sample clocked COD ~1,931 mg/L, BOD₅ ~1,242 mg/L, and free cyanide ~5.3 mg/L (iwaponline.com). By contrast, blast‑furnace blowdown in one study had moderate organics (COD ~54 mg/L) but very high salts (TDS ~6,445 mg/L) (iwaponline.com).
The watchlist has these major pollutants: COD, NH₃‑N, phenols, cyanide, TSS, oils and heavy metals (pmc.ncbi.nlm.nih.gov). Strict discharge standards usually mean BOD/COD in the tens of mg/L, oils <5–10 mg/L, cyanide <0.2 mg/L and heavy metals (Zn, Cu, Ni, Cr, etc.) <0.1 mg/L.
Influent equalization and screening
A large equalization basin (hours to days retention) is the shock absorber. It buffers flow and strength peaks, blends streams and stabilizes pH before downstream units. In practice, designs allow, for example, 6–12 h of retention at peak flow to flatten surges.
Primary hardware starts with physical separation, screens and grit, to keep debris out of hydraulics. This is the domain of systems like waste‑water physical separation. Where debris loads fluctuate, plants standardize on continuous removal with an automatic screen.
API–DAF oil removal train
An API separator (gravity oil–water separator) goes first to lift free and non‑emulsified oil (droplets ≳150 µm) by buoyancy. Good API design (for example, length/width ≥5:1) can remove most floating oil and settle solids. It usually removes 60–80% or more of the “free” oil, depending on droplet size and retention time.
To tighten oil targets, a chemically aided Dissolved Air Flotation (DAF) follows. With coagulant addition (polyaluminium/ferric salt + polymer), DAF can treat influents with oil and grease up to ~500 mg/L. It removes ≥90–95% of residual oil and TSS (parsianfarab.com). On the equipment side, compact skids such as a DAF unit are standard in these trains.
Multi‑stage oil removal, gravity then flotation, routinely drives effluent oil to ≪10 mg/L. Where gravity separation needs a boost, plants add dedicated oil removal modules to strip free oil before flotation.
Chemical precipitation of heavy metals
Metals come out next with pH adjustment and coagulant dosing. Lime or caustic nudges pH to 8.5–10. Sulfide or ferrous iron pushes metals to form insoluble hydroxides/sulfides. Ferric chloride or alum flocculants then agglomerate colloids. Coagulation–flocculation is a conventional, cost‑effective heavy‑metal treatment (pmc.ncbi.nlm.nih.gov).
For the coagulant, operators usually choose polyaluminium salts, such as PAC for industrial wastewater. Polymers help the floc build and settle, and our programs are built around flocculants.
Precision matters at this stage. Metal removal trains usually meter reagents through a dosing pump so the pH stays stable and the coagulant feed is steady.
The numbers guide the design. One coke-oven effluent in a cited study carried about 1.53 mg/L Zn (iwaponline.com). A well-operated lime or sulfide precipitation step usually reduces dissolved Zn (and similar metals) by over 90%. The aim is <0.1 mg/L in the effluent. The metal-rich sludge is thickened or filtered, then disposed or recycled.
Anaerobic front‑end for high COD
For high‑strength organics, the plant uses anaerobic oxidation. A high‑rate anaerobic reactor such as UASB (upflow anaerobic sludge blanket) or EGSB (expanded granular sludge bed), or an anaerobic baffled reactor, usually runs at 20–40 °C. It handles very high COD loads and produces biogas. UASB systems usually remove about 60–90% of COD from extremely polluted streams.
In one full‑scale integrated steel WWTP, an anaerobic/anoxic front‑end achieved ~90% COD reduction and 88% NH₄⁺ removal (iwaponline.com). Anaerobic options in this slot include modular packages such as waste‑water biological digestion.
The anaerobic effluent still contains biodegradable organics and ammonia (from cyanide/chloride oxidation). These pass to aerobic treatment.
Aerobic nitrification and denitrification
A subsequent aerobic bioreactor completes COD removal and converts ammonia to nitrogen. It can be activated sludge (suspended growth), SBR (sequencing batch reactor) or an oxidation ditch. Typical schemes include A²/O (anaerobic–anoxic–oxic) or similar hybrids.
In the cited pilot and full-scale plants, the combined system drove NH₄⁺-N from about 278 mg/L down to about 1.7 mg/L (about 99% removal). Residual COD fell to <100 mg/L (iwaponline.com). Conventional basins work with activated sludge for BOD/COD polishing and nitrification.
Denitrification (an anoxic zone with supplemental carbon) removes produced nitrate. Total nitrogen then comes out in the low single digits mg/L. Overall, hybrid biological trains usually achieve 85–95% reduction of COD/BOD and >90% of ammonia. Effluent COD is then on the order of a few tens of mg/L (iwaponline.com).
Attached-growth reactors, such as biofilm towers or MBBR (moving bed biofilm reactor), hold up under cyanide and phenol loads. Options such as moving bed bioreactors (MBBR) give stable nitrification together with carbon removal.
Cyanide and phenols management
[Cyanide and volatile phenols](https://beta.co.id/en/blog/inside-the-race-to-strip-cyanide-and-phenols-from-steel-wastewater) are toxic at low ppm. They also break down in the bio-process. One hybrid aerobic system removed about 99% of free cyanide (iwaponline.com). In practice, an anaerobic step can convert metal-complex cyanides to simpler forms. The nitrification and oxidation that follow then degrade cyanate to N₂/CO₂.
Polishing filtration and adsorption
After biological treatment, solid/liquid filtration (for example sand filtration or membrane filtration) removes the remaining flocs. Turbidity and SS then come out at <5 mg/L. Plants usually add beds built on sand/silica filtration media to capture fines.
Where a tighter particulate cut is needed, operators use low‑pressure membranes, for example ultrafiltration, as a polishing step before final discharge or reuse.
Activated carbon adsorption targets trace organics and dissolved cyanide. GAC or powdered AC columns remove residual phenols, thiocyanates and complex organics. Systems based on activated carbon do this job. Adsorption trials on bio‑treated coke plant effluent achieved up to ~70% phenol and ~80% total cyanide removal at moderate contact times (www.mdpi.com). In full‑scale practice, multi‑stage carbon polishing (usually combined with aeration/oxidation) reduces phenols and CN to below regulatory detection limits (<0.1–0.2 mg/L) on top of prior treatment.
Performance snapshot and compliance
The overall performance of this centralized scheme is high. Numerical examples from pilot/full plants indicate effluent routinely meeting strict targets: COD <50–100 mg/L, BOD <20–30 mg/L, NH₄⁺ <5 mg/L, cyanide <0.2 mg/L and metals <0.1 mg/L.
In one documented case, the treated effluent reached ~98 mg/L COD and ~1.7 mg/L ammonia (from influent 1,230 and 279 mg/L, respectively) (iwaponline.com). DAF pretreatment to 500 mg/L organics removed ~95% of oils/solids (parsianfarab.com), and AC polishing removed ~80% of remaining phenolics/CN (www.mdpi.com).
The process data show high removal efficiencies: more than 90% for organics and N, and more than 99% for cyanide (iwaponline.com). Therefore the final effluent stays well within typical Indonesian or international discharge standards. These standards usually need less than 0.1–0.5 mg/L for CN and heavy metals, and tens of mg/L for COD/BOD.
Sources and citations
We used authoritative industry and research reports. For example, Colla et al. report about 28.6 m³/tonne water use in integrated steel (www.mdpi.com). Mondal et al. (2021) give a detailed effluent characterization (Table 1) for coke and blast‑furnace streams (iwaponline.com) (iwaponline.com). Reviews of treatment methods (Oladimeji et al., 2024; Pawar et al., 2022) describe coagulation for metals (pmc.ncbi.nlm.nih.gov) and hybrid bioreactors for COD/N and CN removal (iwaponline.com) (www.mdpi.com). These confirm the high removal rates cited above. All cited values, for example percent removals and influent/effluent concentrations, come from these peer‑reviewed sources to support the plant design strategy.