Article
Inside the high‑purity water play powering Indonesia’s CCGTs
Inside the high‑purity water play powering Indonesia’s CCGTs
CCGTs use about 1–2 L/kWh of water, but they need ultra‑pure makeup water to protect high‑pressure boilers. A brackish‑water RO retrofit in East Java shows the economics and the design blueprint for treatment trains that reach <0.1 μS/cm conductivity and <20 ppb silica.
In combined‑cycle gas turbine plants (CCGTs; gas turbine plus steam cycle), water looks deceptively simple. The machines are relatively water‑efficient at ~1–2 L/kWh (thundersaidenergy.com), but the [steam side is unforgiving](https://beta.co.id/en/blog/the-ppb-problem-why-steam-purity-makes-or-breaks-turbines-in-ammonia-plants): [any impurity in makeup water](https://beta.co.id/en/blog/ccgts-ppb-problem-why-ultrapure-steam-makes-or-breaks-turbine-output) can trigger scale and corrosion across high‑pressure boilers and turbogenerators.
That purity requirement meets scarcity. In Indonesia, agriculture uses >70% of the available supply (researchgate.net), so utilities need to prioritize reuse and efficient treatment. One example is the Grati CCGT in East Java. It retrofitted a brackish‑water RO on its WWTP effluent. This cut effluent conductivity from ~500 μS/cm to <20 μS/cm, reused 50% of the wastewater (~1,600 m³/month) and saved IDR 320 million/year with a 5‑year payback (papers.iafor.org, papers.iafor.org). A move like that fits boiler‑feed targets that are usually set at <0.1 μS/cm conductivity and <20 ppb silica (ebrary.net, ebrary.net).
This design guide is for water treatment specialists. It uses industry sources to set out pretreatment, core demineralization and final polishing, with the parameters and trade‑offs that CCGTs need.
Makeup purity targets and local constraints
CCGT makeup systems are built to deliver ultra‑pure water to the HRSG (heat recovery steam generator, the steam generator that recovers heat from gas turbine exhaust). OEM guidelines usually need <0.1 μS/cm conductivity and <10–20 ppb silica, with sodium usually <5 ppb (ebrary.net, ebrary.net). Indonesia is a water‑stressed environment (agriculture takes >70% of supply, researchgate.net). In such places reuse can cut raw water intake by a lot. The brackish‑water RO retrofit at Grati shows this (papers.iafor.org, see also papers.iafor.org). Such retrofits fit brackish service well, so brackish-water RO is a natural choice in power settings.
A CCGT uses about 1–2 L/kWh (thundersaidenergy.com). However, the seasons can cause problems. River TDS (total dissolved solids, the sum of dissolved ions) can rise about 4× during a drought (power-eng.com). Therefore the treatment train must be sized for the averages and for the outliers.
Raw water characterization and pretreatment train
Start with a full analysis: suspended solids, hardness, silica, chloride and organics. Also check how they swing over the seasons. Pretreatment strips particulates and fouling agents. This protects the membranes and resins downstream (power-eng.com, power-eng.com).
For high-turbidity sources, coagulation/flocculation is followed by a clarifier designed at a surface overflow rate of ~5–10 m³/m²·h. Turbidity usually falls to ~1–5 NTU (Nephelometric Turbidity Units, a measure of cloudiness). Without good clarification, the particulate load can blind filters or RO membranes.
Clarifier effluent usually goes to multimedia filtration. A dual‑media bed with sand media beneath anthracite catches the remaining turbidity. Plants report clarifier and filter effluent at about 0.3–1.0 NTU. Well‑designed filters reliably give less than 0.5 NTU (power-eng.com). Multi‑layer designs with anthracite media run longer and help protect the elements downstream.
Many modern lines add microfiltration or ultrafiltration (UF, pressure‑driven membranes that remove fine particles and colloids) ahead of RO (reverse osmosis, a high‑pressure membrane that rejects dissolved ions). One case showed that swapping a sand filter for UF dropped turbidity to ~0.03 NTU. It also stretched RO cartridge changeouts from ~3 weeks to ~3 months (power-eng.com, power-eng.com).
Activated carbon is used to remove chlorine and organics upstream of membranes and ion exchange. In practice, plants use activated carbon before final fine filtration. A 5–20 µm cartridge filter then captures the remaining fines (power-eng.com). Plants may also dose antiscalant and adjust the pH before RO to stop scale. A dosing pump helps keep this tight, and where applicable membrane antiscalants are used.
Each pretreatment step should be sized for peak flow with redundancy. The plant also needs to balance the loss‑of‑charge and backwash requirements against uptime. Coagulant dose and filter area change with turbidity, hardness, TOC (total organic carbon), iron, and manganese in the raw source. Fig. 3 below shows the contemporary design. It uses micro/UF upstream of RO to keep suspended solids very low. Therefore the cartridge filters last months (power-eng.com, power-eng.com).
Core demineralization: IX versus RO (and CEDI)
Bulk demineralization usually follows one of two ways. The first is ion exchange, where resins swap ions in the water with ions on a solid. The second is membranes. Traditional two‑bed IX uses strong‑acid cation in Na⁺ form (softens and acidifies) followed by strong‑base anion in OH⁻ form (power-eng.com). Typical mixed‑bed goals are >20 kgr·eq capacity per m³ of resin. Run lengths depend on raw TDS and flow. Regeneration uses HCl or H₂SO₄ for SAC and NaOH for SBA. It consumes chemicals and produces dilute brine waste. Conventional two‑bed systems can deliver outlet conductivity ~0.5–2 µS/cm (power-eng.com). However, they need frequent regeneration when treating tens–hundreds of mg/L TDS. Plants that choose IX can get complete systems from ion exchange packages, and choose resins from ion-exchange resin portfolios.
Mixed‑bed polishing uses a single vessel that mixes cation and anion resins. It reaches near‑equilibrium purity of about 18 MΩ·cm (about 0.055 µS/cm). It removes the residual ions and meets ASME‑grade feed (silica <10–20 ppb, pH ~9) (ebrary.net, ebrary.net). Vendors usually swap the portable resin “bottles”, so no regeneration is done on site (power-eng.com). Note: mixed beds regenerate even more frequently than two‑bed systems, because the resin utilization is higher. Their brine waste may need neutralization if Title V regulations apply. For a packaged unit, the final polisher is available as a mixed-bed unit. The integrated deionizer is offered as a demineralizer.
Membranes are now common in power makeup trains. Reverse osmosis rejects about 95–99% of dissolved salts. It produces 1–2 µS/cm permeate, which greatly reduces the loading on any downstream IX resins (power-eng.com). One study found that RO ahead of IX "greatly reduced loading on the IX resins". That cut the regeneration frequency and the chemical demand (power-eng.com). RO also removes more than 90% of silica and TOC, which usually cause trouble in IX. RO+CEDI (continuous electrodeionization) removes more silica and dissolved organics than IX alone (power-eng.com, power-eng.com). RO does produce a concentrate stream of about 20–30% of the feed. It also needs pump energy of about 0.5–5 kWh/m³. CEDI uses about 1 MJ/m³, compared with 20–50 MJ/m³ for a high-pressure RO pump (power-eng.com). For typical river water, practical RO recovery is about 80–90%. That balances the intake against the scaling risk and the concentrate disposal.
Modern plants usually combine RO with either a final mixed bed or CEDI. CEDI gives "chemical‑free" continuous polishing to mixed‑bed purity. However, it needs very low hardness, which is usually achieved only after RO, and it is sensitive to organics and chlorine (power-eng.com, power-eng.com). Packaged EDI units and membrane lines from membrane systems portfolios are standard in new builds.
Selection ultimately depends on raw TDS and economics (power-eng.com). Low‑TDS feeds (<~200–300 mg/L) usually favor conventional IX. Where solids are higher, or the pressure to curb chemical waste is stronger, RO pre‑treatment with IX or CEDI polish is preferred. Many new CCGTs follow the "post‑RO + portable mixed‑bed" model (power-eng.com). This reflects the shift toward membranes (power-eng.com, power-eng.com).
Final polishing and conditioning steps
If CEDI is not used, a mixed‑bed ion exchanger on RO permeate drives conductivity well below 0.1 µS/cm and holds silica in the single‑digit ppb range (ebrary.net, ebrary.net). Service companies usually swap these “bottles” every month. Plants may also use a condensate polisher to protect quality during upsets.
Dissolved gases are managed by deaeration. The demineralized stream is pre‑heated and fed to a liquid deaerator (spray or steam‑heated). This takes O₂ to <20 ppb. An oxygen scavenger (hydrazine or organic sulfite) is dosed afterward (ebrary.net). Some high‑pressure HRSG designs use vacuum or membrane degasifiers, but liquid deaeration is standard.
Demineralized feedwater is usually volatiles‑treated (AVT‑Na, where volatile chemicals are added for pH control) in CCGTs. Ammonia (and sometimes hiding O₂ scavengers) is added to reach ~9.4 pH. This gives ~9.6 in the LP drum (ebrary.net). Cation conductivity (<0.2 µS/cm after degassing) is trended to detect ionic leaks.
Final units are sized for boiler‑feed flow. Resin holds and cartridges are specified to ride through upsets (for example, membrane flushes). Continuous analyzers for conductivity, silica and pH with alarm setpoints, plus automated blowdowns based on these signals, keep quality on spec. As a rule of thumb, ultimate maxima follow OEM boiler/HRSG guidance: <0.1 µS/cm conductivity, silica <10–20 ppb, Na <5 ppb (ebrary.net, ebrary.net).
Waste, energy, and regulatory trade‑offs
IX regeneration produces spent acids and bases, roughly 1–2 m³ of regenerant per 100 m³ treated. Plants usually neutralize this and discharge it under NPDES permits. RO creates a high‑TDS concentrate, about 10–30% of the feed, that needs disposal, for example evaporation ponds or sewer if permitted. In Indonesia, the effluent limits on flow and salt load matter. Many plants recycle regenerant between beds or reuse RO concentrate for non‑important makeup, for example in cooling towers, to reduce discharges.
Energy matters too. Pumping and treatment usually use less than 2% of plant output. RO pumps are one of the larger auxiliary draws. High-efficiency pumps and VSDs can move the needle. CEDI units use about 1 MJ/m³, but a high-pressure RO pump can use 20–50 MJ/m³ (power-eng.com). If local electricity tariffs are high, these figures affect the IX-versus-RO trade-off.
Water reuse is a strategic lever. The Grati BWRO project reused 50% of wastewater (~1,600 m³/month) and dropped conductivity from ~500 μS/cm to <20 μS/cm. It saved IDR 320 million/year with a 5‑year payback (papers.iafor.org, papers.iafor.org). This shows the business case for retrofits.
On standards, Indonesia does not impose a unique boiler‑feedwater spec beyond international codes. However, environmental permits emphasize water‑use efficiency and discharge limits. The government’s PROPER program rewards pollution reduction, and a gold rating needs minimal effluent. Designs that drive toward near‑zero liquid discharge, for example by reusing brine, can yield reputational and regulatory benefits. Teams should consult ESDM (Energy Ministry) and KLHK (Environment) on effluent quality and handle any B3 (hazardous) waste per government standards.
Reliability is operational. As [40] notes, operator skill and monitoring are important (power-eng.com). Build in redundancy: parallel filters, IX vessels and RO skids. Then one unit can go offline without starving the HRSG. Automate IX regenerations and RO cleanings. Include cross‑connects for bypass or interstage feed. Add digital control for predictive maintenance, for example tracking resin capacity exhaustion or RO flux decline.
Best‑practice configuration and metrics
Good pretreatment combines coagulation and flocculation with a clarifier and multimedia filters. Many sites add UF to give less than 0.5 NTU feed, and less than 0.1 NTU is ideal to protect membranes and resins (power-eng.com). The core demineralization usually runs on RO as a first stage (single or two‑pass depending on raw TDS), followed by IX polishing. RO+CEDI or RO+mixed‑bed has increasingly replaced conventional two‑bed systems (power-eng.com, power-eng.com). This uses less chemical and produces 10–15 MΩ·cm‑quality water. Membrane‑first lines work well with modular membrane systems.
Final polish brings feed conductivity to much less than 0.1 μS/cm and silica to less than 10–20 ppb (ebrary.net, ebrary.net). Deaeration then brings O₂ to less than 20 ppb, and pH is adjusted to ~9.4. Continuous analyzers and automated blowdowns close the loop. Supporting equipment and spares from water treatment ancillaries help keep uptime.
Sustainability measures reduce freshwater intake. These include recycling backwash or regenerant streams and using non‑traditional sources, for example treated municipal or industrial effluent. The plant at Grati shows this (papers.iafor.org, papers.iafor.org). If discharge limits tighten, you can consider designing for ZLD (zero liquid discharge) by adding evaporators or crystallizers on the RO brine.
Plants can hit stringent chemistry specs and cut chemical and energy costs. They do this by matching pretreatment to raw water swings, right‑sizing IX/RO/CEDI, and tightening final polish and controls. The specs include ASTM/ASME‑aligned targets at ebrary.net and ebrary.net. Industry reports note that modern membranes and continuous deionization improve both quality and environmental performance (power-eng.com, power-eng.com).
Sources: industry and regulatory references as cited above. These include papers.iafor.org, ebrary.net, power-eng.com, power-eng.com, power-eng.com and power-eng.com.