Steelmaking draws 20–30 m³ of water per tonne and recycles ≈90%. The rest is a tough residue loaded with solids and metals. A three-stage plant turns that mix into compliant effluent and reusable water. The stages are primary clarification, chemical precipitation and tertiary polishing.
Steelmaking uses a lot of water. Per tonne of steel, water intake can be 20–30 m³, mostly for cooling and scrubbing (mdpi.com). In practice ≈90% of that is recycled or evaporated (mdpi.com). However, the remainder carries suspended solids and dissolved metals. Typical pollutants include iron oxides, [oil/grease, cyanides from pickling, and heavy metals](https://beta.co.id/en/blog/inside-the-steel-mill-that-cleans-oil-metals-and-cyanide-by-design) (Zn, Ni, Cr, Cu, Pb, etc.) at tens to hundreds of mg/L (milligrams per liter). One case study reports Fe ~309 mg/L, Zn ~40 mg/L, Cr(VI) ~10.9 mg/L, and Pb ~20.5 mg/L (researchgate.net).
Meeting discharge rules is hard. Indonesia's standards (Permen LHK No.5/2014) cap Fe and Zn at ≤10 mg/L, Ni, Cd, and Cr⁶⁺ at ≤0.5–1.0 mg/L, and TSS (total suspended solids) at ≤400 mg/L (scribd.com) (scribd.com). In practice, treated steel effluent can stay well below those limits. One producer reported about 0.1–0.3 mg/L for Fe, Zn, and Ni (scribd.com) (scribd.com). Peer-reviewed reviews and industry guidance describe both the scale and the contaminants (mdpi.com).
Designing the wastewater treatment plant is not optional. It is an exercise in hydraulics, chemistry, and polishing. Screens and grit removal come first, then clarification to remove solids, reagent dosing to precipitate metals, and membranes or filters to finish the job. For front-end debris control, engineered screens and skimming are standard (screens and primary separation).
Primary clarification and thickening design
After screening and grit removal, wastewater enters sedimentation tanks. These are clarifiers: gravity settling units that remove settleable solids. They are usually circular or rectangular, with mechanical scrapers or inclined plates (nepis.epa.gov). In steel applications, well-sized units run at a surface loading of about 1–2 m³/m²·hr with 30–60 minutes detention. They remove about 75–90% TSS, similar to lagoon performance (nepis.epa.gov). Many plants use standard basins built to last, supported by a clarifier package.
Coagulation and flocculation add chemicals that neutralize charges and bind fine particles. This pushes more solids into the settleable size range. Polymers and ferric/alum coagulants are common. A coke-plant trial at pH≈9 using lime ~1.7 g/L achieved 94% TSS removal and 86% COD (chemical oxygen demand) removal (researchgate.net). Upstream dosing usually relies on a dedicated chemical dosing pump. Polymers are sourced as flocculants and metal salts as coagulants.
Where a smaller footprint is necessary, inclined-plate modules (lamella settlers) raise capacity by increasing the settling area. Plants usually fit compact units such as a lamella settler into clarifier galleries. This raises throughput without major civil works.
Sludge drawn off the clarifiers is thickened before dewatering, from about 1–3% to about 4–8% solids. This cuts handling costs. The gain shows up at once. One Indonesian operator reported TSS of about 10–17 mg/L after the clarifier, against a 400 mg/L limit (scribd.com).
Chemical precipitation of dissolved metals
The second stage targets dissolved ions. Chemical precipitation is widely used in steel wastewater. It converts dissolved metals into insoluble compounds (nepis.epa.gov). Plants raise [pH into the 9–10 range](https://beta.co.id/en/blog/inside-the-ph-10-play-how-coal-prep-plants-turn-blowdown-into-compliant-discharge) using lime (CaO), caustic soda, or sodium carbonate. This forces Fe, Zn, Cu, Ni, Mn, Pb, Cd and others into metal hydroxides. In batch tests, ~1–3 g CaO per liter has delivered >85–95% metal removal with residual pH ~8–10 (researchgate.net) (nepis.epa.gov). Metering reliability at this point depends on a stable dosing pump and accurate pH control. pH is the acidity/alkalinity scale.
Sometimes hexavalent chromium (Cr⁶⁺) or metals that resist hydroxide precipitation are present. Then sulfide reagents (Na₂S, NaHS or ferrous sulfide) form metal sulfides with far lower solubility. Sulfide can reduce and precipitate Cr⁶⁺ directly, without a separate reduction step (nepis.epa.gov) (nepis.epa.gov). The stream is mixed in a reactor for ~30–60 minutes. Then a polymer is added to form settleable floc, and the stream is clarified, usually with inclined plates to intensify separation.
Results are consistently low metals. Final effluent Ni ~0.05–0.10 mg/L and Zn ~0.02–0.18 mg/L have been reported from raw levels orders of magnitude higher (scribd.com) (scribd.com). Co‑precipitation with other solids also removes anions (F⁻, PO₄³⁻, phenols as soaps) and residual oils. This drives overall removal to >80–99% for target metals and >90% for remaining solids (researchgate.net) (nepis.epa.gov).
Tertiary polishing and water reuse
Polishing closes the compliance gap. Multimedia filtration strips the remaining fines. Designs usually specify a sand layer and a hard coal top layer. Plants standardize media such as sand/silica and then use post-adsorption with granular activated carbon for trace organics or any adsorbable metals.
For trace ions, adsorption media like zeolites or ion-exchange resins are used. Operations usually stock ion-exchange resins for polishing duty. Where ultra-low discharge or reuse is the target, a membrane train follows. Ultrafiltration (UF, a pressure-driven membrane that removes colloids and microbes) comes before reverse osmosis (RO, the high-rejection membrane for salts). Many plants use UF skids and a brackish-water RO set for TDS control. One integrated process, constructed wetland + UF + RO, reported ~75% metal removal and ~98% salt removal and produced reusable water (researchgate.net).
Ozonation, UV/H₂O₂ or dechlorination, if needed, cleans up refractory organics. Plants use ultraviolet systems for low‑cost, non-chemical disinfection and oxidation polishing, usually with a UV unit. These steps drive phenol and cyanide to <0.1 mg/L before discharge (researchgate.net).
Where biological oxygen demand (BOD) is material, designers add an aerobic polish such as activated sludge (a suspended-growth bioreactor) or a nitrifying filter. In practice, final BOD levels of 6–30 mg/L against a 150 mg/L limit show a modest aerobic block (scribd.com). Engineered biological units usually remove 90%+ of BOD/COD (chemical oxygen demand) (scribd.com) (researchgate.net). Compact aeration trains are usually built around an activated-sludge module.
Therefore mills get higher water re-use rates and move toward zero-liquid-discharge (mdpi.com) (researchgate.net).
Sludge handling and solids management
All removed contaminants go to sludge. The sludge is a mix of metal hydroxides, sand, oil and organics. Primary and precipitation sludges are thickened first, usually from about 1–3% to about 4–8% solids, and then dewatered. Mechanical presses are standard. One large steelmaker uses a filter press to turn wet sludge into a dry cake (scribd.com). Typical cake solids are 15–25%. This is suitable for haulage and landfill or co‑processing. Some sites market iron‑rich sludges and furnace dusts as non‑hazardous byproducts, aligned to Indonesian rules that reclassify EAF dust and slag as non‑B3 waste.
Design allowances matter. Sludge yields usually sit around 5–20 kg dry per tonne of steel. Thickeners and presses take about 10–20% of the WWTP footprint and power. The centrate is recovered and recycled to the headworks. The dry solids go to recovery or disposal as per regulation.
Performance metrics and design parameters
A well‑designed train consistently beats the standards. Typical final effluent is TSS about 10–20 mg/L, TDS (total dissolved solids) about 300 mg/L, and pH about 7–8. Fe, Mn, Zn, Ni and Pb are all well below 0.2 mg/L (scribd.com) (scribd.com). BOD/COD are about 10–50 mg/L against limits of 150/300 (scribd.com).
Track these key metrics: percent removal by parameter (target >90% for TSS and metals), effluent mg/L by species, and treated flow versus design. Hydraulic sizing uses proven anchors. The clarifier overflow rate (Q/A) is about 1–2 m³/m²·hr and detention is 30–60 minutes. Chemical setpoints include pH 9–10 and reagent mass per liter estimated from influent loads (nepis.epa.gov) (nepis.epa.gov) (mdpi.com). Designs are data‑driven. Tank volumes, dosing rates and filter selections are justified by pilot tests or literature values as above.
The literature base is broad. It covers peer‑reviewed reviews and government guidance on steel effluent chemistry and unit processes (mdpi.com) (mdpi.com) (nepis.epa.gov) (nepis.epa.gov). It also covers national standards and plant performance reports (scribd.com) (scribd.com), and case studies on lime treatment and reuse trains (researchgate.net) (researchgate.net) (researchgate.net). These sources give the numbers we need for design: removal efficiencies, effluent concentrations and water usage rates.