WhatsApp

Article

Pharma’s new DSP math: small columns, big gains — and the case for single‑use

beta-pramesti-asiaindustry-pharmaceuticalprocess-downstream-processing

Pharma downstream trimmed: 80% less resin, 3–5× faster, and CAPEX costs down by tens of percent

Small, fast multi-column chromatography, resin used across batches, and single-use replacing CIP. Industry data show sharp savings without compromising quality.

Downstream processing (DSP, the purification stage after production) is more and more a place where efficiency is won. Three moves now stand out: small chromatography columns that cycle fast, resin reused across batches and products, and single-use (SU) components that remove CIP and validation.

Evidence from industry and academia agrees. One chromatography manufacturer reports that resin needs can fall by up to 80% with multi-column chromatography (MCC) compared with a single large column. The same source reports the production rate rising about 3×. Read that figure as a vendor-side upper bound. It is not a result guaranteed in every process. On the operational side, one real-world mAb clarification case replaced a conventional TFF (tangential flow filtration) skid with pre-sterilized cassettes. That cut labor by ~50% and buffer use by ~75% (BioPharm International).

An economic simulation of an end-to-end continuous antibody plant (multi-column based) shows a ~38% reduction in cost-of-goods/COGs (production cost per unit), ~17% lower capital requirements, and ~40% higher annual output than a conventional process (end-to-end continuous bioprocessing analysis for mAb).

Rapid-cycling multi-column

MCC (multi-column chromatography, several small columns in series or parallel) keeps each column cycling through loading, elution and regeneration. No resin sits idle as it does in a single-column batch. Because loading, elution and regeneration run at the same time in different columns, resin demand falls and throughput rises compared with a single large column.

The rapid cycling chromatography (RCC, fast cycling, including simulated moving-bed/SMB) concept follows the principle of "more with less". RCC membrane media studies report productivity of ~10–20 g/L·h in batch mode, and RCC convective matrices shorten cycle time and raise overall output. Figures such as "up to 80% resin cost" and "3× productivity" come from column manufacturers' marketing materials. Use them as upper bounds, not design benchmarks.

From a regulatory standpoint, MCC can be used as an in-line ("drop-in") replacement for a single-column system.

Multi-batch and cross-product resin

Chromatography media, especially Protein A (~US$5–$10k per liter), is a main target for cost savings. Industry surveys show many Protein A columns are retired after only 3–20 cycles, although validated lifetimes reach 100–200 cycles (aiche.onlinelibrary.wiley.com). The multiproduct resin reuse (MRR) approach addresses this waste. The same resin is used one after another for different antibodies, with rigorous cleaning between them.

The technical evidence is solid. Ravi et al. (2023) tested a proof of concept on an 18.7 mL Protein A column. Three IgG1 mAbs (immunoglobulin G1 monoclonal antibodies) were run for a total of 90 cycles (~30 per molecule), with standard NaOH (sodium hydroxide) cleaning between products (aiche.onlinelibrary.wiley.com). Through cycle 90, process results, impurity levels and product quality stayed constant. There was no adverse trend in yield, aggregates or HCP (host cell proteins) (aiche.onlinelibrary.wiley.com).

Protein carryover between batches was always below 0.014% (aiche.onlinelibrary.wiley.com), well below common safety thresholds. For context, carryover below 1000 ppm is considered acceptable (aiche.onlinelibrary.wiley.com). The business impact is straightforward. Resin purchases are less frequent and repacking is unnecessary. For a 100 L Protein A column (US$10k/L), extending its life from 10→100 cycles saves almost US$900 thousand.

Avoiding unpack/repack between campaigns also cuts downtime. Ravi et al. estimate that a validated changeover can cut facility throughput by up to 50% (downtime up to 50%) because of cleaning/regeneration and re-equilibration steps (aiche.onlinelibrary.wiley.com). MRR needs a risk assessment and cleaning validation. However, detailed guidance is available (aiche.onlinelibrary.wiley.com) (aiche.onlinelibrary.wiley.com). Other studies show that anion/cation-exchange media can be cleaned to regulatory standards between two products (aiche.onlinelibrary.wiley.com) (aiche.onlinelibrary.wiley.com). Industry authors also state that reuse can “very much reduce resin waste and cost” in clinical and commercial manufacturing (aiche.onlinelibrary.wiley.com).

Verified single-use equipment

Single-use (SU) equipment arrives pre-sterilized and is discarded after one use. This covers bags, filters and pre-packed columns. Therefore cleaning-in-place/CIP systems for fixed equipment are greatly reduced. Industry experts highlight the reduced need for “cleaning/cleaning validation” for SU membranes and containers. This raises productivity and cuts energy, water and labor (BioPharm International). Those savings come from less equipment being washed. They do not come from validation obligations disappearing.

NNE Pharmaplan estimates that initial CAPEX for SU facilities is about 30% lower than for all-stainless systems (PharmTech). Piping, CIP skids, steam generators and large tanks can be reduced. The space footprint in cleanroom areas also falls by 30–50% (PharmTech).

One operational example: replacing a conventional TFF skid with pre-sterilized cassettes cuts labor by about 50% and buffer by about 75% (BioPharm International). The current generation of SU TFF cassettes is about 4–5× cheaper per unit than the early generation (BioPharm International). SU components also shift costs from fixed equipment to variable supplies. This is useful for small-volume and fast-moving projects (BioPharm International). In multi-product practice, changing sterile bags takes minutes, not hours for CIP and qualification.

Market adoption reflects this trend. In 2024, about 87% of biomanufacturing facilities reported using SU technology (PharmaManufacturing). The COVID vaccine surge boosted this. Adoption is now beginning to level off as the technology matures. Therefore some work shifts from steam utilities and CIP to handling single-use components, extractables testing and sterility testing.

In Indonesia, CPOB (Cara Pembuatan Obat yang Baik) follows international guidelines that need validated cleaning between lots. Single-use systems reduce that burden. No fixed equipment has to be dismantled and cleaned between products, so cleaning steps drop a lot. One thing to understand: single-use does not remove the need for validation and contamination control. Single-use components are used once, but they still need qualification, an integrity check, and they must stay sterile and clean on every use. This includes extractables/leachables data (EU GMP Annex 1). In multi-product facilities, SU racks or single-use columns can cut batch cycle time and reduce changeover risk.

The important point in single-use facilities is actually the water. TFF cassettes, buffers, and their final rinses meet process water: purified water and, where needed, WFI (water for injection). A common train is RO followed by EDI (electrodeionization) to reach low conductivity without chemical regeneration. Industrial water demineralization is an option when capacity and raw water quality need an ion-exchange train. For food and process water applications, carbon filters that can be sanitized with steam (steam sanitizable) are available for food and beverage industrial water treatment and water reuse. Raw water analysis, flow rate, conductivity target and waste limits determine the configuration, not the component brand.

Measurable impact on cost

Taken together, the impact is quantitative. Multi-column capture can cut resin inventory by up to 80% according to vendor claims. Run multiplexing also drives output up several-fold. Media reuse (for example Protein A) can extend the total number of cycles by an order of magnitude. That cuts media costs by tens of percent. Even if it only doubles the number of cycles, media cost per batch is halved. SU systems lower CAPEX by tens of percent and increase facility utilization. One analysis found that a continuous SU facility can deliver a >40% reduction in COGs compared with a conventional batch process (end-to-end continuous mAb analysis). This comes mainly through integration and a simpler flow.

Real-world case: switching to SU TFF cassettes cuts labor by ~50% and buffer by ~75% (BioPharm International). It also reduces equipment load and CIP waste. Overall, modern DSP intensification enables 30–80% savings on key cost drivers. Therefore it justifies investment in new equipment and workflows. ASEAN manufacturers (including Indonesia) are increasingly examining these options to remain globally competitive under CPOB guidelines.

Source notes and links

Sources: Ravi, N. et al. (2023) and Li, H. et al. (2024) in Biotechnology Progress. End-to-end continuous bioprocessing analysis for mAb. Single-Use panel in BioPharm International. PharmTech on single-use technology costs. PharmaManufacturing on SU adoption in 2024. And the BioPlan Associates 21st Annual Report. Links: Biotechnology Progress (btpr.3333), Biotechnology Progress (btpr.3434), end-to-end continuous mAb analysis, BioPharm International, PharmTech, PharmaManufacturing.