Grease Trap Commercial Kitchens

Updated

Grease traps for commercial kitchens separate fats and oils before drainage. Select capacity, cleaning access, and wastewater-treatment needs with Beta.

Grease Trap Commercial Kitchens

Discuss the application.

Send the application, operating conditions and the result you expect. Our team will discuss the options with you.

Ask about this product

or use the contact page

Grease Trap for Commercial Kitchens

A grease trap captures fats, oils, grease and floating solids before kitchen wastewater enters drainage piping or downstream treatment. PT Beta Pramesti Asia provides grease traps for commercial kitchens and water-treatment facilities. Capacity and configuration should match peak flow, kitchen activity, available installation space and the cleaning method available to operators.

What is a grease trap and how does it work?

A grease trap is a separation tank that holds back fats, oils, grease and floating solids from kitchen wastewater before it reaches drainage or downstream treatment. Wastewater enters, grease separates and floats, solids are screened or settle, and clearer water flows out. Grease keeps accumulating. Therefore the unit must be inspected and emptied before its working volume drops.

What size grease trap does a kitchen need?

There is no single size for every kitchen. Size comes from peak wastewater flow multiplied by retention time. Then it is checked against grease-holding capacity and the emptying interval. Peak flow, operating hours, kitchen equipment, grease and solids load, and available space all change the result. Seat count alone is not enough. A step-by-step guide (in Indonesian) is in the article cara menghitung ukuran grease trap dapur.

Information needed to select a grease trap

Selection should not rely on the unit’s physical size alone. The project team should review peak wastewater flow, kitchen equipment and activity, operating hours, installation location, access for emptying, and the pipe route to the wastewater plant. This information helps make sure retained grease can be removed routinely before it disrupts flow or downstream treatment.

ConsiderationWhy it matters
Peak flow and meal-time patternDetermines the required holding capacity and separation time.
Fats, oils, grease, and solids from kitchen activityDefines the solids-screening need and cleaning frequency.
Location and service accessEnsures the unit can be inspected and emptied without disrupting operations.
Treatment after the grease trapAligns the grease trap with DAF or the wastewater-treatment process where needed.

Grease trap types and how to choose

We size for kitchens and water-treatment facilities. The three design bases differ in how the unit is calculated, installed and cleaned:

Unit typeSuitsNeedsCleaning
Hydromechanical unit inside the building (PDI G101)Kitchens with several sinks or discharge points handled individuallyCalculation from each fixture’s volume, a unit selected above the calculated flow, plus a flow-control fitting and solids screenAll grease and solids are removed when the unit is emptied, then the inlet and outlet are checked.
Gravity grease interceptor outside the building (PDI G101)Combined flow from several kitchen points routed to one unit outside the buildingA separation time of 30 minutes or more, land, emptying access, and ventilationAll grease and solids are emptied, then the inlet, outlet, and vent are checked.
Grease separator to EN 1825-2Kitchens and water-treatment facilities where EN 1825-2 is the specified standardNominal size (NS) from the maximum flow, taking wastewater temperature, grease density, and detergent effect into accountSurface grease and the sludge space at the bottom are emptied; the interval follows holding capacity divided by daily grease generation.

Access and size have separate effects. If the emptying access is difficult, cleaning is delayed. If the unit is too small, it loses retention time at peak flow and carries grease downstream.

Keeping a grease trap effective

A grease trap remains effective when accumulated grease and solids are removed before they reduce its working volume. Set an inspection routine based on kitchen load, record cleaning results, and check for bypass flow or settled solids restricting the inlet or outlet. If kitchen wastewater still has a high fats-and-oils load after initial separation, review the need for downstream treatment with a wastewater specialist.

BETAGARD 5350

Grease Trap

BETAGARD 5350 protects pipes from blockages and corrosion. This grease trap uses grease separation to keep fats and oils out of your piping system.

Discuss a grease trap and kitchen-wastewater treatment

Send the flow data, layout, kitchen type and drainage conditions to Beta Pramesti’s wastewater-treatment team. We will discuss the grease trap and any downstream process requirements with you.