How pharma proves centrifuges and filters are truly clean — and regulators are watching

beta-pramesti-asiaindustry-pharmaceuticalprocess-centrifugation-dan-filtration

How pharma proves centrifuges and filters are truly clean — and regulators are watching

Plants prove their CIP/COP cycles with riboflavin spray tests and HPLC that measures nanograms per swab. The aim is to keep potent APIs off shared equipment. This data-first approach is now standard from Jakarta to New Jersey.

Industry: Pharmaceutical | Process: Centrifugation_&_Filtration

Cross-contamination is not a theoretical risk in multi-product drug plants. It is a GMP red line. Cleaning on stainless equipment is important to prevent carryover of potent APIs (active pharmaceutical ingredients) on shared centrifuges and filtration trains, according to industry literature (pmc.ncbi.nlm.nih.gov).

Regulatory expectations are harmonized. Indonesia's GMP (CPOB) explicitly aligns with PIC/S (Pharmaceutical Inspection Co‑operation Scheme) and WHO guidance. The latest CPOB (BPOM Reg. 34/2018) is based on PIC/S GMP doc. PE009‑16 (2022) (klikcpob.pom.go.id). Therefore cleaning procedures for centrifuges and filter skids must be developed, validated and verified "drug‑free" with science, not faith.

Modern Clean‑in‑Place (CIP, automated spray and recirculation cleaning) has been used since the 1950s. It gives better compliance, less downtime, lower water and detergent consumption, and less manual labor than old-school manual washdowns (www.tsaprocessequipments.com). In one validated case, the conductivity of the final rinse matched purified water. That is a strong signal that the detergents were fully removed (www.pharmtech.com).

CIP and COP: definitions and trade‑offs

CIP (Clean‑in‑Place) cleans equipment in place with fixed spray balls or nozzles and pumped recirculation, without taking it apart. It suits large enclosed systems such as centrifuge bowls, piping and filter skids. It gives repeatable results and needs less labour. COP (Clean‑out‑of‑Place) takes components apart for manual or assisted cleaning, by immersion, brushing or ultrasonics. COP reaches complex shapes but adds handling and variation. Many plants use a mix of both: CIP for vessels and loops, and COP for sensitive removable parts such as membranes and seals when needed (www.pharmtech.com).

On filtration skids built for pharma, sanitary housings matter. High‑pressure sanitary assemblies such as 316L stainless cartridge housings are built for CIP and for documented cleanability in validation.

The GMP context is clear. CPOB follows a PIC/S-aligned framework and draws on risk-based ICH principles (for example ICH Q7A/Q9) and EMA/ICH guidance. Regulators stress design for cleanability, documented procedures and scientifically justified residue limits. These limits are increasingly based on health-based ADE/PDE (acceptable/permitted daily exposure) rather than arbitrary numbers (klikcpob.pom.go.id) (www.pharmtech.com) (www.pharmtech.com).

Risk‑based procedure development

Validation starts with a risk and flow assessment: API potency, solubility and toxicity, equipment geometry such as dead‑legs, seals and joints, and exposure points. Centrifuge OEMs advise pre‑commissioning risk analyses with users. These include riboflavin (a fluorescent tracer) spray coverage tests to show shadowed areas (process-technology-online.com).

Design helps. One “VBC” centrifuge uses an inclined basket with integral self‑cleaning spray nozzles and hygienic seals. Rinsing, spraying, scraping, suction and even steam flushing can reach the internal surfaces (process-technology-online.com) (process-technology-online.com). Good practice sets the spray ball placement, the recirculation loops, the fast‑drain features and the minimum dead‑legs.

For COP, disassembly targets parts like seals or filter elements. Removable elements such as a cartridge filter can be brushed or ultrasonicated in validated sinks with specified detergents. The SOP sets the temperature, the time and the number of passes.

Worst‑case selection is central. Plants validate against the hardest‑to‑remove or most hazardous API (for example, lowest solubility, highest potency) to cover all routine products (pmc.ncbi.nlm.nih.gov). One case identified the very water‑insoluble and toxic Oxcarbazepine as the worst case for shared lab equipment, and a partnering company reinforced that choice (pmc.ncbi.nlm.nih.gov).

Validated CIP sequence parameters

A representative CIP cycle follows a controlled sequence. First a pre‑rinse with water (usually warm) removes bulk product. Then a detergent wash follows, where heated caustic or enzymatic detergent is recirculated for a fixed time (for example, 30–60 minutes) at controlled temperature and concentration. Intermediate rinses come next. An acid wash or sanitizing step follows if needed (for example, pH below 3 for passivation or scale removal). Then a final rinse with purified water runs until analytics confirm clean. Drying comes last (air blow‑out or vacuum).

One validated one‑pot processor example: 35 L of 40 °C water for prewash, about 80 L of 60 °C alkaline detergent (pH ~12.5), and ~110 L of rinse water (60 L cold wash + 50 L final rinse). The cycle lasted ~90 minutes plus ~30 minutes drying. It removed both a water‑soluble drug (theophylline) and a water‑insoluble drug (mebendazole) below acceptance levels (www.pharmtech.com) (www.pharmtech.com).

Statistical reproducibility and controls

Validation needs reproducibility, usually three consecutive runs. In one data set, four consecutive theophylline batches were cleaned and sampled. Low variance in residues confirmed robustness. Deviations like a 24‑hour delay before cleaning were also challenged (www.pharmtech.com).

Automated CIP logs the important parameters: pump flow, temperature, detergent strength and time. These are usually in SCADA (supervisory control and data acquisition), so every cycle is the same. A dosing pump usually meters the detergent feed accurately. COP depends on training and on following the SOPs every time.

Surface sampling: swab and rinse methods

PIC/S accepts two complementary approaches for residue recovery on equipment: direct swab (wipe) sampling and indirect rinse (flush) sampling (gmpua.com) (process-technology-online.com).

Swab sampling means wiping a defined area, usually 25–100 cm², with a pre‑wetted inert swab (polyester or cotton). The swab is chosen with a solvent that matches the API chemistry for recovery (gmpua.com) (pmc.ncbi.nlm.nih.gov). One protocol moistened a swab with 2 mL water and wiped a 100 cm² stainless area with horizontal and vertical strokes. Both sides of the swab were then extracted in solvent for 10 minutes (or ultrasonicated), filtered and analyzed (pmc.ncbi.nlm.nih.gov) (pmc.ncbi.nlm.nih.gov). Swabbing physically dislodges dried or insoluble deposits. However, it introduces operator variability and needs swab material blanks.

Rinse sampling washes or flushes a known solvent volume over or through the wetted surfaces of the equipment, then collects it for analysis. In closed systems, the final rinse water can be collected. For open vessels, a defined volume is applied. One lab protocol used two sequential 5 mL washes (10 seconds each), a total of 10 mL per item (gmpua.com) (pmc.ncbi.nlm.nih.gov). Rinse tests are reproducible and reach hidden areas. However, they rely on sufficient residue solubility in the chosen solvent (gmpua.com) (gmpua.com).

In practice, the best approach is a combination of swab for hard‑to‑reach or insoluble residues and rinse for full‑system coverage (gmpua.com) (gmpua.com).

Analytical assays and method validation

GMP needs validated, specific analytical methods with sensitivity at or below the acceptance limit (pubmed.ncbi.nlm.nih.gov). For small-molecule APIs, HPLC/UPLC (high/ultra‑performance liquid chromatography) with UV, tandem MS or other detectors is typical. Published examples report detection down to single ng per swab (www.pharmtech.com) (pmc.ncbi.nlm.nih.gov). GC–MS (gas chromatography–mass spectrometry) is used if residues are volatile or semi‑volatile.

Non-specific checks such as TOC (total organic carbon) and conductivity confirm overall organic and inorganic cleanliness. This includes API, excipients and cleaning agents (pubmed.ncbi.nlm.nih.gov) (pmc.ncbi.nlm.nih.gov). In the one-pot processor example, the final rinse conductivity matched purified water. Therefore no detergent remained (www.pharmtech.com). Some plants install online monitors, such as in-column TOC or conductivity probes, to control CIP in real time (process-technology-online.com).

Each assay must be validated for accuracy, precision, linearity and LOD/LOQ fit for the limit. Swab and rinse recovery is documented by spiking stainless coupons or real surfaces. This usually shows ≥70–80% recovery for the combined sampling and analysis process (pmc.ncbi.nlm.nih.gov). For high-potency APIs, LC–MS/MS (liquid chromatography–tandem mass spectrometry) is used more and more to reach lower detection limits.

Acceptance criteria and health‑based limits

Older examples use criteria such as no visible residue, ≤10 ppm in the next product, ≤0.001× daily dose, or a fixed surface limit (historically ~1 µg/cm²) (www.pharmtech.com) (www.pharmtech.com). Current practice favors health‑based ADE/PDE (acceptable/permitted daily exposure) over fixed ppm rules (www.pharmtech.com).

Examples from the literature: an absolute surface limit of 1 µg/cm² for the active and 10 ppm for detergent in the one‑pot processor case (www.pharmtech.com). In another study the threshold for Oxcarbazepine is 10 ppm (0.01 mg/mL), based on its PDE. Regulators accept that very sensitive assays may detect tiny residues. A result is acceptable if it sits below the scientifically justified limit. Zero is not needed (www.pharmtech.com) (www.pharmtech.com).

Performance data bears this out. In the one‑pot processor CIP, all important surfaces (filter, impeller blade, chopper, bowl, valve cover) showed theophylline residues well below the 1 µg/cm² limit, even with a 24‑hour cleaning delay (www.pharmtech.com). A few hard‑to‑wet spots (impeller wingnut, bowl seal) had slightly higher variation but stayed under the limit (www.pharmtech.com). One design feature, the impeller lipseal, exceeded the limit for the water‑soluble drug but not for the insoluble one. Therefore that zone needs better optimization or better CIP coverage (www.pharmtech.com).

Outcomes, efficiency, and audit readiness

A good CIP/COP program gives hard metrics: “<X ppb of API on all surfaces” or “no growth in final rinse cultures”. It also reduces occupational exposure and cuts downtime. The validated CIP above used about 200 L of water and detergent in total and fit within a single production shift. Manual soaking sometimes takes days (www.pharmtech.com) (www.pharmtech.com).

Quality teams benefit from harmonized, data‑rich documentation: cleaning maps, swab and rinse results, and validated HPLC/TOC/conductivity assays aligned to ADE/PDE‑based limits. Re‑qualification on a defined cadence (for example annually or after an equipment change) verifies performance over time. For sterile operations, biological assurance (BI challenge tests of sterilization steps) or ATP swabs may be part of the wider control strategy. However, they sit outside chemical residue testing.

Risk-based CIP/COP methods, sampling strategies endorsed by PIC/S, and quantitative analytics prove that equipment is clean. They also keep plants audit-ready in Indonesia and globally (klikcpob.pom.go.id) (gmpua.com) (process-technology-online.com) (www.tsaprocessequipments.com).