Rinse water from metal finishing can carry tens to hundreds of mg/L of nickel, zinc, and chromium. Indonesia sets limits of ≤1.0 mg/L metals, ≤0.1 mg/L Cr(VI), and ≤0.2 mg/L cyanide. To meet them, the system needs a strict order: segregation, cyanide oxidation, chromium reduction, high‑pH precipitation, solids removal, and polishing.
Electroplating effluent is not just “dirty water.” It is a complex chemical soup with dissolved heavy metals and specialty additives that shift hour by hour. [Typical plating rinse waters](https://beta.co.id/en/blog/inside-the-metal-finishing-plant-redesigning-its-rinse-waterand-its-risk-profile) can contain tens to hundreds of mg/L of Ni, Zn and Cr (III), according to the CPCB Industry Document on Electroplating Industries. Indonesian standards (Permen LH No. 5 Tahun 2014) ratchet discharge targets down to single‑mg/L and sub‑mg/L territory. Total nickel and zinc ≤1.0 mg/L, hexavalent chromium ≤0.1 mg/L, and cyanide ≤0.2 mg/L ([peraturan.bpk.go.id](https://peraturan.bpk.go.id/Details/322442/permen-lh-no-5-tahun-2014)). The math is relentless. The system must pull off >90–99% removal, stream after stream.
The industry answer is conventional but chemistry‑intense: collect and condition the flows, oxidize cyanide, reduce Cr(VI), precipitate metals by pH adjustment (with optional selective precipitants), separate the solids, and polish the effluent. The same sequence is the basis of U.S. EPA "conventional" metal‑finishing treatment systems, per www.sterc.org.
Influent profile and discharge limits
Plating waste can also contain cyanides from cyanide‑based baths, on top of high Ni/Zn/Cr(III). The regulations are strict: nickel and zinc at ≤1.0 mg/L, hexavalent chromium at ≤0.1 mg/L, cyanide at ≤0.2 mg/L (peraturan.bpk.go.id). To hit those numbers, the treatment train must remove more than 90–99% of each contaminant every time. A well‑operated chemical precipitation system, combined with cyanide oxidation, is designed to do that (www.sterc.org).
Segregation, equalization, and pretreatment
All rinse and process wastes are best buffered in an equalization tank (or tanks) to smooth fluctuations in pH and loading. Very alkaline or acidic streams can be neutralized before the main treatment. Cyanide‑bearing rinses are routed to a dedicated cyanide unit so they don’t interfere with downstream precipitation, and Cr(VI) streams are likewise segregated for reduction (www.sterc.org). Chemical addition across these steps relies on precise dosing. In practice, operators use chemical dosing equipment such as dosing pumps to control pH setpoints and reagent feeds.
Cyanide oxidation (alkaline chlorination)
Free cyanide (CN⁻) is destroyed first, under tightly controlled alkalinity to avoid HCN off-gassing. Alkaline chlorination uses NaOCl or Cl₂ at pH≈10–11. It is the proven workhorse (www.sterc.org). In a two-stage reactor, the first tank converts CN⁻ to cyanate (CNO⁻): NaCN + NaOCl → NaCNO + NaCl. In the second stage, more hypochlorite completes the reaction: 2 NaCNO + 3 NaOCl + H₂O → 3 NaCl + N₂↑ + 2 NaHCO₃. The equations come from industry references at www.sterc.org.
Stoichiometry demands about 7.5 lb NaOCl (≈7 lb Cl₂) per 1 lb CN removed. In practice a 25–100% excess is common to drive completion (www.sterc.org). Operating doses usually reach 10–20 mg/L as free chlorine and destroy >95% of CN. Properly managed systems reduce cyanide from industrial levels (for example 50–200 mg/L) down to trace levels (www.sterc.org). Alternatives like hydrogen peroxide or ozone exist but are less common in plating operations (www.sterc.org).
Chromium reduction (bisulfite at low pH)
Hexavalent chromium stays soluble as chromate and must be converted to Cr(III) before precipitation. A reducing agent, usually sulfur dioxide or sodium bisulfite, is dosed at pH≈2–3 to reduce Cr⁶⁺ to Cr³⁺ (www.sterc.org). A representative reaction: 3 NaHSO₃ + 2 H₂CrO₄ + 3 H₂SO₄ → Cr₂(SO₄)₃ + 5 H₂O + 3 NaHSO₄, operated at pH 2–3 (www.sterc.org). Well‑designed reduction routinely delivers Cr(VI) <0.1 mg/L (www.sterc.org).
Metal precipitation (hydroxides and selective sulfides)
Once CN is oxidized and Cr(VI) reduced, metals are precipitated by high‑pH chemistry. Hydroxide precipitation is the industry standard. Raising pH with NaOH or Ca(OH)₂ forms insoluble metal hydroxides (M(OH)₂) that can settle (www.sterc.org, link.springer.com). The core reaction is M²⁺ + 2 OH⁻ → M(OH)₂↓.
The pH setpoints matter. Ni²⁺ and Zn²⁺ usually form Ni(OH)₂ and Zn(OH)₂ at about pH 9–10. Reduced Cr³⁺ precipitates as Cr(OH)₃ at about pH 6–8. Many systems raise the pH in steps. For example, they go to 6.5–7 first to capture Cr³⁺, then to 9–10 for the remaining metals. Most plants use sodium hydroxide (84% of surveyed plants). Lime is also common for cost or buffering, and some plants use lime only (www.sterc.org). As a sizing reference: removing 1 mg/L Ni would theoretically consume about 1.3 mg/L as Ca(OH)₂ (molecular weights 58.7 vs 74). Therefore a 100 m³/d plant treating 50 mg/L Ni and 50 mg/L Zn would need about 100–200 kg/d of Ca(OH)₂ to reach pH~10. Jar tests fine-tune the dose for each wastewater (link.springer.com).
When residual targets are very low (≪0.1 mg/L), selective sulfide precipitation can push Ni/Cu/Zn lower. Metal sulfides have solubilities orders of magnitude below the hydroxides. Typical reagents include Na₂S or NaHS, or organosulfur precipitants such as thiocarbonates and dithiocarbamates (link.springer.com, link.springer.com). These must be dosed carefully to avoid H₂S gas. However, they can drive effluent to very low μg/L. In conventional practice, most shops rely on hydroxide precipitation. Only a few use sulfides routinely (www.sterc.org).
Flocculation, clarification, and sludge handling
After precipitation, a polymer flocculant binds the fine hydroxide particles so they settle and separate better. Many designs do this in a clarifier, and packaged units like a clarifier work the same way. The supernatant is then decanted. It is routine to specify the flocculation step with purpose-formulated polymers. Suppliers of flocculants help you reach the target particle size and settling rates described in this stage.
The metal hydroxide sludge is then thickened (for example with a gravity thickener) and dewatered (for example with a filter press or a centrifuge). The sludge is rich in Ni/Zn/Cr hydroxides. After dewatering it usually exceeds 70% solids. It is hazardous, so it must be stabilized and landfilled or processed further. Some operators recover Zn, Ni and other metals from the sludge. Sludge volume is about 5–10 kg of dry solids per 1000 L of wastewater treated.
Final polishing and TDS considerations
The clarified effluent is pH‑adjusted to about 6–9 and then polished as needed. Activated carbon is usually used to remove residual organics or complexants. Media such as activated carbon do this job. Membrane filtration can be added where absolute metal targets must be met. In high‑end systems, polishing ion exchange or ultrafiltration can bring trace metals below 0.1 mg/L. The options include resin platforms such as ion exchange resins or ultrafiltration modules such as ultrafiltration. TDS and chlorides stay high, usually 1000–3000 mg/L, and precipitation does not remove them. Where reuse or tighter discharge needs it, [reverse osmosis can be added](https://beta.co.id/en/blog/steels-thirst-meets-its-new-playbook-membranes-math-and-a-march-to-zld). Industrial units such as brackish-water RO are typical in this role.
Performance benchmarks and chemical economics
Hydroxide precipitation can remove more than 90–99% of Ni, Cu, Zn and Cr(III) from plating waste (www.sterc.org. See also the CPCB Comprehensive Industry Document on Electroplating Industries). Industry reports suggest that a well-run lime or caustic precipitation step usually brings final Ni, Zn and Cu down to the sub-mg/L range (CPCB Comprehensive Industry Document on Electroplating Industries). For Cr(VI), the usual reduction and precipitation steps meet the <0.1 mg/L effluent target every time (www.sterc.org). Cyanide oxidation also destroys more than 99%. After alkaline chlorination the residual CN is usually <1 mg/L, and in many cases only trace levels, well below the 0.2 mg/L standard (www.sterc.org).
In practice, a medium-size electroplating plant, for example 1000 m³/day, might receive 50–100 mg/L of each metal. After treatment it could discharge Ni and Zn at ≤0.5–1.0 mg/L, Cr(III) at <0.3 mg/L and CN at <0.1 mg/L. These figures align with Indonesian and international limits (peraturan.bpk.go.id. See also www.sterc.org).
Chemical consumption drives the design. About 1.2–1.4 kg CaO/NaOH is needed per kg of divalent metal removed (2 OH⁻ per metal) (link.springer.com). Cyanide oxidation at 50–100 mg/L CN needs about 0.75–1.5 kg NaOCl per 1000 L (7.5 kg NaOCl per kg CN) (www.sterc.org). In a case study, chemicals were about 85–90% of the operating cost (CPCB Comprehensive Industry Document on Electroplating Industries). Treatment cost depends on the metal and cyanide load, the reagent dose, power and B3 sludge disposal. For an estimate for your installation, request a quote.
Standards and literature basis
Design choices here follow regulatory and technical guidance. Indonesian Permen LH No. 5 Tahun 2014 (see Table 1) sets the effluent limits we refer to (peraturan.bpk.go.id). U.S. EPA "Conventional" metal-finishing systems use the sequence Cr reduction → CN oxidation → hydroxide precipitation (www.sterc.org). Hydroxide precipitation is described as "the standard method of removing heavy metals" and is used in 75% of plating systems (www.sterc.org). Sulfide precipitation can reach even lower residuals (link.springer.com). Cyanide oxidation chemistry and economics are well-documented (www.sterc.org). Together, these data-driven elements support equipment and chemical sizing that meets stringent environmental standards. Sources include regulatory texts (Permen LH 5/2014 and CPCB electroplating ERP) and industry literature (EPA/STER C studies www.sterc.org, www.sterc.org, www.sterc.org, and treatment summaries at link.springer.com and link.springer.com). Indonesian discharge values come from national regulations (peraturan.bpk.go.id).
To turn these numbers into doses and setpoints, start with a bench-scale jar test. The PAC and ACH coagulants used in the flocculation stage are in our coagulant catalogue.